00192375-01 - 第66页

SIPLACE GEM for S25, HS50 SW Version GEM 502.01 HOST Inter face Manual Page 66 of 236 ©Siem ens AG, all rights reser ved 7RZHU - A MTC has 2 Towers. Values 1,2 Used in MTCInf o 07&BQXPEHU - Num ber to identify a MTC …

100%1 / 236
SIPLACE GEM for S25, HS50 SW Version GEM 502.01
HOST Interface Manual
©Siemens AG, all rights reserved page 65 of 236
3 = Denied. At least one CEID link already defined
4 = Denied. At least one CEID does not exist
5 = Denied. At least one RPTID does not exist
>5 = Other errors
6 - 63 reserved
used in: S2F36
/9$&. - Variable limit definition acknowledge code
Format: B[1]
1 = Variable does not exist
2 = Variable has no limits capability
3 = Variable repeated in message
4 = Limit value error as desired in LIMITACK
5 - 63 reserved
used in: S2F46
0DFKLQH6LGH - Side of the machine
Format: U1
0 = right side in transport direction
1 = left side in transport direction
0D[%DOO'HY - Maximal ball deviation
MaxBallDev is calculated by the vision system during the optical centering of a package
form. It is calculated over all balls in all ball groups.
Format: F8
Units are 1/1000 mm
used in: PLACEINFOREVx,
0D[/HDG'HY - Maximum lead deviation
MaxLeadDev is calculate by the vision system during the optical centering of a package
form. It is calculate over all leads in all lead groups.
Format: F8
Units are 1/1000 mm
used in: PLACEINFOREVx,
0'/1 - Equipment Model Type
Format: A
used in: S1F2, S1F13, S1F14, S1F65, S1F66
0+($' - Message block header associated with block in error
Format: B[16]
used in: S9F1, S9F3, S9F5, S9F7, S9F11
0,' - Lot ID
Format: A[16]
used in S2F27
SIPLACE GEM for S25, HS50 SW Version GEM 502.01
HOST Interface Manual
Page 66 of 236 ©Siemens AG, all rights reserved
7RZHU - A MTC has 2 Towers.
Values 1,2
Used in MTCInfo
07&BQXPEHU - Number to identify a MTC
This number corresponds to the value of LOCATION
Format: U1
Values 1,2,3,4
Used in MTCInfo
QRWBFXELFBQR]]OH Vacuum value for a nozzle
vacuum threshold for melfs, etc.
Format: I4
Units are mbar
used in : VACUUMDATEREVx
12==/(B7<3(: - Number of a nozzle
For a detailed description see SIPLACE Placement Stations - Data Interface: Chapter
Nozzle Types.
Format: U4
used in : NOZZLECONFx, NOZZLERETURN,
21/$&. Acknowledge for code for ON-LINE request
Format: B[1]
0 = Accepted
1 = Denied
2 = Equipment already ON-LINE
3 - 63 reserved
used in S1F18
RSHQBQR]]OH Vacuum value for a nozzle
vacuum value measured with an open nozzle
Format: I4
Units are mbar
used in : VACUUMDATEREVx
2SWLFDO(UURUVNumber of optical errors since last download of a process program
Format: U2
used in: PICKUPERRORSLOCx
2UWKR'HY - Orthogonal deviation
Format: F8
Units are 1/100 degree
used in : PLACEINFOREV1, PLACEINFOREV2, PLACEINFOIC
3DFNDJH)RUP1XPEHU - Identifier for a package form
Format: U2
see chapter 9 in the SIPLACE Data Interface ( <pack_form_no>).
SIPLACE GEM for S25, HS50 SW Version GEM 502.01
HOST Interface Manual
©Siemens AG, all rights reserved page 67 of 236
used in: PLACEINFOREVx
3LFN(UURUVNumber of pickup errors per segment since the current PCB reached the
center conveyor.
Format:I2
used in : SEGMENTINFOREVx
3LFN8S(UURUVNumber of pick-up errors since last download of a process program
Format: U2
used in: PICKUPERRORSLOCx
3LFN8S5HVXOW - Result of the pick up action
Format : U1
0 NOK (default value)
1 OK
2 NOK
used in : PLACEINFOREVx
3LFN8S9DFFXP - Vaccum measured at pick-up position.
PickUpVacuum is measured in the pick up circuit after a component is picked up
Format : I4
Units are mbar
used in : PICKUPINFOREVx
3LWFKBSHUBOHDGBJURXS- Distance between leads.
During the optical centering of a package the vision system calculate the average
distance between the leads within a lead group.
Format: I4
used in : PLACEINFOREVx
3/$&((5525'(6&5,37,21 Description of an placement error.
Format : U2
2 : Visionerror
3 : Vacuumerror
In case of both errors at the same time, a visionerror will be reported
3ODFH(UURUVNumber of place errors per segment since the current PCB reached the
center conveyor.
Format:I2
used in : SEGMENTINFOREVx
3ODFHPHQW5HVXOW - Result of the placement action
Format : U1
1 : Component placed
2 : Component was thrown away, because of an detected error
used in : PLACEINFOREVx