SIPLACE GEM for S25, HS50 SW Version GEM 502.01 HOST Inter face Manual ©Siemens AG, all rights reserved page 67 of 236 used in: PLACEINFOREVx 3LFN(UURUV Num ber of pick up err ors per s egm ent since the cur rent PCB …

SIPLACE GEM for S25, HS50 SW Version GEM 502.01
HOST Interface Manual
Page 66 of 236 ©Siemens AG, all rights reserved
7RZHU - A MTC has 2 Towers.
Values 1,2
Used in MTCInfo
07&BQXPEHU - Number to identify a MTC
This number corresponds to the value of LOCATION
Format: U1
Values 1,2,3,4
Used in MTCInfo
QRWBFXELFBQR]]OH Vacuum value for a nozzle
vacuum threshold for melfs, etc.
Format: I4
Units are mbar
used in : VACUUMDATEREVx
12==/(B7<3(: - Number of a nozzle
For a detailed description see „SIPLACE Placement Stations - Data Interface: Chapter
Nozzle Types“.
Format: U4
used in : NOZZLECONFx, NOZZLERETURN,
21/$&. Acknowledge for code for ON-LINE request
Format: B[1]
0 = Accepted
1 = Denied
2 = Equipment already ON-LINE
3 - 63 reserved
used in S1F18
RSHQBQR]]OH Vacuum value for a nozzle
vacuum value measured with an open nozzle
Format: I4
Units are mbar
used in : VACUUMDATEREVx
2SWLFDO(UURUVNumber of optical errors since last download of a process program
Format: U2
used in: PICKUPERRORSLOCx
2UWKR'HY - Orthogonal deviation
Format: F8
Units are 1/100 degree
used in : PLACEINFOREV1, PLACEINFOREV2, PLACEINFOIC
3DFNDJH)RUP1XPEHU - Identifier for a package form
Format: U2
see chapter 9 in the SIPLACE Data Interface ( <pack_form_no>).

SIPLACE GEM for S25, HS50 SW Version GEM 502.01
HOST Interface Manual
©Siemens AG, all rights reserved page 67 of 236
used in: PLACEINFOREVx
3LFN(UURUVNumber of pickup errors per segment since the current PCB reached the
center conveyor.
Format:I2
used in : SEGMENTINFOREVx
3LFN8S(UURUVNumber of pick-up errors since last download of a process program
Format: U2
used in: PICKUPERRORSLOCx
3LFN8S5HVXOW - Result of the pick up action
Format : U1
0 NOK (default value)
1 OK
2 NOK
used in : PLACEINFOREVx
3LFN8S9DFFXP - Vaccum measured at pick-up position.
PickUpVacuum is measured in the pick up circuit after a component is picked up
Format : I4
Units are mbar
used in : PICKUPINFOREVx
3LWFKBSHUBOHDGBJURXS- Distance between leads.
During the optical centering of a package the vision system calculate the average
distance between the leads within a lead group.
Format: I4
used in : PLACEINFOREVx
3/$&((5525'(6&5,37,21 – Description of an placement error.
Format : U2
2 : Visionerror
3 : Vacuumerror
In case of both errors at the same time, a visionerror will be reported
3ODFH(UURUVNumber of place errors per segment since the current PCB reached the
center conveyor.
Format:I2
used in : SEGMENTINFOREVx
3ODFHPHQW5HVXOW - Result of the placement action
Format : U1
1 : Component placed
2 : Component was thrown away, because of an detected error
used in : PLACEINFOREVx

SIPLACE GEM for S25, HS50 SW Version GEM 502.01
HOST Interface Manual
Page 68 of 236 ©Siemens AG, all rights reserved
3ODFHPHQW9DFFXP - Vacuum measured during placement.
Format : I4
PlacementVacuum is measured in the placement circuit before the component is placed.
UNITS are mbar
used in : PLACEINFOREVx
33%2'< - Process Program Body
Format: A
used in: S7F3, S7F6
33*17 - Process Program Grant
Format: B[1]
0=OK
1 = already have
2 = no space
3 = invalid PPID
4 = busy, try later
5 = will not accept
>5 other error
6 - 63 reserved
used in: S7F2
33,' - Process Program ID
Format: A[8]
used in: S2F27, S7F1, S7F3, S7F5, S7F6, S7F17, S7F20
357,' - Report ID
Format: U4
used in: S2F33, S2F35, S6F3, S6F9, S6F11, S6F13, S5F16, S6F18, S6F19, S6F21
4XDOLW\ - Measurement result of a package form or a fiducial
Quality ranges between 0 and 100. The higher the value, the better the fiducial was
recognized.
Format: U1
used in: PLACEINFOREVx, FIDUCIALDATA
5&0' - Remote Command
Format: A
used in: SsF21, S2F41
5HDO1R]]OH/HQJWK - measured nozzle length
The nozzle length is measured during the reference run. It depends on the
HEIGHTREVOLER value. So REAL_NOZZLE_LENGTH is not a absolute but a relative
value.
It is calculated by subtracting the measured difference between the nozzle and the upper
edge of the conveyor belt from the HEIGHTREVOLER value.
Format: I4
Units are 1/1000 mm