00192375-01 - 第68页
SIPLACE GEM for S25, HS50 SW Version GEM 502.01 HOST Inter face Manual Page 68 of 236 ©Siem ens AG, all rights reser ved 3ODFHPHQW9DFFXP - Vac uum m easured during plac em ent. Form at : I4 Placem entVacuum is m eas ured…

SIPLACE GEM for S25, HS50 SW Version GEM 502.01
HOST Interface Manual
©Siemens AG, all rights reserved page 67 of 236
used in: PLACEINFOREVx
3LFN(UURUVNumber of pickup errors per segment since the current PCB reached the
center conveyor.
Format:I2
used in : SEGMENTINFOREVx
3LFN8S(UURUVNumber of pick-up errors since last download of a process program
Format: U2
used in: PICKUPERRORSLOCx
3LFN8S5HVXOW - Result of the pick up action
Format : U1
0 NOK (default value)
1 OK
2 NOK
used in : PLACEINFOREVx
3LFN8S9DFFXP - Vaccum measured at pick-up position.
PickUpVacuum is measured in the pick up circuit after a component is picked up
Format : I4
Units are mbar
used in : PICKUPINFOREVx
3LWFKBSHUBOHDGBJURXS- Distance between leads.
During the optical centering of a package the vision system calculate the average
distance between the leads within a lead group.
Format: I4
used in : PLACEINFOREVx
3/$&((5525'(6&5,37,21 – Description of an placement error.
Format : U2
2 : Visionerror
3 : Vacuumerror
In case of both errors at the same time, a visionerror will be reported
3ODFH(UURUVNumber of place errors per segment since the current PCB reached the
center conveyor.
Format:I2
used in : SEGMENTINFOREVx
3ODFHPHQW5HVXOW - Result of the placement action
Format : U1
1 : Component placed
2 : Component was thrown away, because of an detected error
used in : PLACEINFOREVx

SIPLACE GEM for S25, HS50 SW Version GEM 502.01
HOST Interface Manual
Page 68 of 236 ©Siemens AG, all rights reserved
3ODFHPHQW9DFFXP - Vacuum measured during placement.
Format : I4
PlacementVacuum is measured in the placement circuit before the component is placed.
UNITS are mbar
used in : PLACEINFOREVx
33%2'< - Process Program Body
Format: A
used in: S7F3, S7F6
33*17 - Process Program Grant
Format: B[1]
0=OK
1 = already have
2 = no space
3 = invalid PPID
4 = busy, try later
5 = will not accept
>5 other error
6 - 63 reserved
used in: S7F2
33,' - Process Program ID
Format: A[8]
used in: S2F27, S7F1, S7F3, S7F5, S7F6, S7F17, S7F20
357,' - Report ID
Format: U4
used in: S2F33, S2F35, S6F3, S6F9, S6F11, S6F13, S5F16, S6F18, S6F19, S6F21
4XDOLW\ - Measurement result of a package form or a fiducial
Quality ranges between 0 and 100. The higher the value, the better the fiducial was
recognized.
Format: U1
used in: PLACEINFOREVx, FIDUCIALDATA
5&0' - Remote Command
Format: A
used in: SsF21, S2F41
5HDO1R]]OH/HQJWK - measured nozzle length
The nozzle length is measured during the reference run. It depends on the
HEIGHTREVOLER value. So REAL_NOZZLE_LENGTH is not a absolute but a relative
value.
It is calculated by subtracting the measured difference between the nozzle and the upper
edge of the conveyor belt from the HEIGHTREVOLER value.
Format: I4
Units are 1/1000 mm

SIPLACE GEM for S25, HS50 SW Version GEM 502.01
HOST Interface Manual
©Siemens AG, all rights reserved page 69 of 236
5HIHUHQFH'HVLJQDWRU - Identifier for a placement position
Format: A
see chapter 5.4 in the SIPLACE Data Interface ( <position_name> in
<placemant_pos_record>).
used in: PLACEINFOREVx
5(3*6= - Reporting group size
Format: U4
used in: S2F23
56'$ - Request Spool Data Acknowledge
Format: B[1]
0=OK
1 = Denied, busy try later
2 = Denied, spooled data does not exist
3 - 63 reserved
used in: S2F24
56'& Request Spool Data Code
Format: B[1]
0 = Transmit Spooled Massages
1 = Purge Spooled Messages
2 - 63 reserved
6(*0(17 – Number of the segment to pick up or place a component.
Format: U1
6+($' - Stored header related to the transaction timer
Format: B[10]
used in: S9F9
603/1 - Sample number
Format : U4
used in: S6F1
62)75(9 - Software revision code
Format: A[6]
used in: S1F2, S1F13, S1F14, S1F65, S1F66
67,0( - Sample time
Format: A[16]
used in: S6F1
675$&. - Spool Stream Acknowledge
Format: B[1]
1 = Spooling not allowed for stream
2 = Stream unknown
3 = Unknown function specified for this stream
4 = Secondary function specified for this stream