SIPLACE GEM for S25, HS50 SW Version GEM 502.01 HOST Inter face Manual Page 70 of 236 ©Siem ens AG, all rights reser ved used in: S6F44 675,' - Stream ID Form at: U1 used in: S2F43, S2F44 69,' - Status Variable…

SIPLACE GEM for S25, HS50 SW Version GEM 502.01
HOST Interface Manual
©Siemens AG, all rights reserved page 69 of 236
5HIHUHQFH'HVLJQDWRU - Identifier for a placement position
Format: A
see chapter 5.4 in the SIPLACE Data Interface ( <position_name> in
<placemant_pos_record>).
used in: PLACEINFOREVx
5(3*6= - Reporting group size
Format: U4
used in: S2F23
56'$ - Request Spool Data Acknowledge
Format: B[1]
0=OK
1 = Denied, busy try later
2 = Denied, spooled data does not exist
3 - 63 reserved
used in: S2F24
56'& Request Spool Data Code
Format: B[1]
0 = Transmit Spooled Massages
1 = Purge Spooled Messages
2 - 63 reserved
6(*0(17 – Number of the segment to pick up or place a component.
Format: U1
6+($' - Stored header related to the transaction timer
Format: B[10]
used in: S9F9
603/1 - Sample number
Format : U4
used in: S6F1
62)75(9 - Software revision code
Format: A[6]
used in: S1F2, S1F13, S1F14, S1F65, S1F66
67,0( - Sample time
Format: A[16]
used in: S6F1
675$&. - Spool Stream Acknowledge
Format: B[1]
1 = Spooling not allowed for stream
2 = Stream unknown
3 = Unknown function specified for this stream
4 = Secondary function specified for this stream

SIPLACE GEM for S25, HS50 SW Version GEM 502.01
HOST Interface Manual
Page 70 of 236 ©Siemens AG, all rights reserved
used in: S6F44
675,' - Stream ID
Format: U1
used in: S2F43, S2F44
69,' - Status Variable ID
Format
used in: S2F23
691$0( - Status variable name
Format: A
used in: S1F12
7(;7 - A single line of characters
Format: A[160]
used in: S10F1, S10F3, S10F5, S10F9
7,$$&. - Equipment Acknowledge Code
Format: B[1]
0 = everything correct
1 = too many SVIDs
2 = no more traces allowed
3 = invalid period
4 - 63 reserved
used in; S2F24
7,$&. - Time Acknowledge Code
Format: B[1]
0=OK
1 = Error, not done
2 - 63 reserved
used in; S2F32
7,' - Terminal ID
Format: B[1]
0 = single or main terminal
>0 = additional terminals on same equipment
used in: S10F1, S10F3, S10F5
727603 - Total sample to be made
Format: U4
used in: S2F23
7UDFN1XPEHU - Number of a track
Format: I2
used in: PICKUPINFO1REVx, PICKUPERRORSLOCx
WROBGLUW\BQR]]OH - vacuum value
Format: I4

SIPLACE GEM for S25, HS50 SW Version GEM 502.01
HOST Interface Manual
©Siemens AG, all rights reserved page 71 of 236
Units are mbar
used in : VACUUMDATEREVx
WROBOHDN\BQR]]OH - vacuum value
Format: I4
Units are mbar
used in : VACUUMDATEREVx
75,' - Trace Request ID
Format: U4
used in: S2F23 S6F1
81,76 - Units of measure
Format: A
used in: S1F12, S2F30, S2F48
833(5'% - Upper boundary of the dead-end of a limit
Format:
used in: S2F45, S2F48
9DFXXP- Vacuum in the holding circuit.
Format: I4
Vacuum is the measured vacuum in the holding circuit.
Units are mbar
used in: PLACEINFOREVx, PICKUPINFOREVx,
VacuumErrors
Number of VacuumErrors.
Used in PICKUPERRORSLOCx (number of vacuum errors only after pickup)
9,' - Variable ID
Format:
used in: S1F3, S1F11, S2F13, S2F15, S2F29, S2F30, S2F33, S2F45, S2F46, S6F3,
S6F13, S6F18, S6F22
9/$$&. - Variable Limit Attribute Acknowledge Code
Format: B[1]
0=OK
1 = Limit attribute definition error
2 = Cannot perform now
3 = Other error
4 - 63 reserved
used in: S2F46
:LGWK- Width of a package form
Width is returned from the vision system. It’s the „optical“ width of the package form.
Units are 1/1000 mm
Format: U4
used in: PLACEINFOREVx