SIPLACE GEM for S25, HS50 SW Version GEM 502.01 HOST Inter face Manual Page 72 of 236 ©Siem ens AG, all rights reser ved ;SRVLWLRQ - X- Coordinate of a placem ent or f iducial position Form at: U4 Units are 1/1000 m m ;…

100%1 / 236
SIPLACE GEM for S25, HS50 SW Version GEM 502.01
HOST Interface Manual
©Siemens AG, all rights reserved page 71 of 236
Units are mbar
used in : VACUUMDATEREVx
WROBOHDN\BQR]]OH - vacuum value
Format: I4
Units are mbar
used in : VACUUMDATEREVx
75,' - Trace Request ID
Format: U4
used in: S2F23 S6F1
81,76 - Units of measure
Format: A
used in: S1F12, S2F30, S2F48
833(5'% - Upper boundary of the dead-end of a limit
Format:
used in: S2F45, S2F48
9DFXXP- Vacuum in the holding circuit.
Format: I4
Vacuum is the measured vacuum in the holding circuit.
Units are mbar
used in: PLACEINFOREVx, PICKUPINFOREVx,
VacuumErrors
Number of VacuumErrors.
Used in PICKUPERRORSLOCx (number of vacuum errors only after pickup)
9,' - Variable ID
Format:
used in: S1F3, S1F11, S2F13, S2F15, S2F29, S2F30, S2F33, S2F45, S2F46, S6F3,
S6F13, S6F18, S6F22
9/$$&. - Variable Limit Attribute Acknowledge Code
Format: B[1]
0=OK
1 = Limit attribute definition error
2 = Cannot perform now
3 = Other error
4 - 63 reserved
used in: S2F46
:LGWK- Width of a package form
Width is returned from the vision system. Its the optical width of the package form.
Units are 1/1000 mm
Format: U4
used in: PLACEINFOREVx
SIPLACE GEM for S25, HS50 SW Version GEM 502.01
HOST Interface Manual
Page 72 of 236 ©Siemens AG, all rights reserved
;SRVLWLRQ - X-Coordinate of a placement or fiducial position
Format: U4
Units are 1/1000 mm
;GHYLDWLRQ - Deviation in X-direction
Format: I4
Units are 1/1000 mm
<SRVLWLRQ - Y-Coordinate of a placement or fiducial position
Format: U4
Units are 1/1000 mm
<GHYLDWLRQ - Deviation in Y-direction
Format: I4
Units are 1/1000 mm
SIPLACE GEM for S25, HS50 SW Version GEM 502.01
HOST Interface Manual
©Siemens AG, all rights reserved page 73 of 236
 6WUHDP
 6)$UH<RX7KHUH
S1F1 W. * H<->E
The Host may send this message to the Equipment at any time.
The SIPLACE sends this message periodically as a "heartbeat" to determine if the SECS
link is operational.
The Equipment Constant ConfigConnect can be set to cause the Equipment to send
S1F1 instead of S1F13 for Connect Request.
 6)2Q/LQH'DWD(TXLSPHQWWR+RVW
S1F2 * H<-E
<L
<A MDLN> * MDLN Model Number
<A SOFTREV> * SOFTREV Software Revision
> .
The Equipment reports its Model Number and Software Revision.
 6)2Q/LQH'DWD+RVWWR(TXLSPHQW
S1F2 * H->E
<L> .
 6)6HOHFWHG6WDWXV5HTXHVW
S1F3 W * H-> E
<L
<U4 VID> * Variable ID
...
> .
The Host requests status from the SIPLACE. The Host sends the VIDs of interest.
Several VIDs can be specified if desired.
Normally, only VIDs of class SV (i.e. Status Variables) are used in this message.
However, the SIPLACE allows the Host to use any VID of class DV, EC, or SV.
If S1F3 contains a zero-length list, then the SIPLACE will report all variables of class SV,
in order by VID.