00194440-10_SM_X-Series_Customer_en - 第146页
Service Work C&P20 Nozzle Changer 3.5.5 Replacing the Three mm Green LEDs [03 021168-xx] 146 Service Manua l SIPLACE X Series 3.5.5 3 . 5 . 5 R e p la c in g t h e T h r e e m m G r e e n L E D s [ 0 3 0 2 1 1 6 8 - …

Service Work
3.5.4 Replacing the Microswitch [03019563-xx] C&P20 Nozzle Changer
Service Manual SIPLACE X Series 145
3.5.4
3.5.4 Replacing the Microswitch [03019563-xx]
Replacing the Microswitch [03019563-xx]
Overview
Removal/Installation
Adjusting the microswitch switching point
▪ Setting gauge [03028340-xx]
NOTICE
All microswitches are soldered into place.
You therefore need to unsolder the individual microswitches. You also need heat-shrinkable
sleeves, to pull over the contacts.
1-6: Microswitches for monitoring the nozzle magazine
(open/closed)
7: 1 wire board
6
5
4
7
1
3
2
1. Two fastening screws
2. Electrical connections
3. Fixing bracket
► Unsolder the electrical connections (2) at the relevant
microswitch.
► Loosen the two screws (1) fastening the microswitch.
► Install the new microswitch on the fixture bracket (3).
► Pull the heat-shrinkable sleeves over the electrical
connections and solder the connections.
► Warm the heat-shrinkable sleeves and make sure
that these cover the contacts tightly.
1
3
2

Service Work
C&P20 Nozzle Changer 3.5.5 Replacing the Three mm Green LEDs [03021168-xx]
146 Service Manual SIPLACE X Series
3.5.5
3.5.5 Replacing the Three mm Green LEDs [03021168-xx]
Replacing the Three mm Green LEDs [03021168-xx]
Removal/installation
1. C&P20 nozzle changer with a free slot for setting
gauge [03028340-xx]
2. Green diode: shines when status is Nozzle changer
closed.
► Instead of the magazine (for which the microswitches
monitor the positions open/closed), attach the setting
gauge to the free nozzle changer slot (1).
NOTICE!
Make sure that all other nozzle changers are attached to
the nozzle changer!
Setting gauge for C&P20 nozzle changer [03028340-xx]
► Press in the lever (3) of the setting gauge. This sim-
ulates a closed magazine.
► Turn the nozzle changer over and carefully place it
down on the installation location, with the magazines
pointing downwards.
► Make sure you do not touch any electrical connec-
tions.
► Switch the machine on.
► Use the two fastening screws to adjust the micros-
witch, so that the green LED (2) shines.
⇨ This ensures that the microswitch switches cor-
rectly.
► Pull out the lever (3) of the setting gauge. This simu-
lates an open magazine.
⇨ Make sure that the green LED (2) does not shine!
1
2
1. Green LED three mm
► Remove the nozzle magazine in the center. The LED
is located beneath (1).
► Remove the cover (2).
► Pull the LED (1) out towards the back.
► Unplug the connection cable.
► Remove the cable ties.
1

Service Work
3.5.6 Replacing the Complete Lever/Toggle [03013445-xx] C&P20 Nozzle Changer
Service Manual SIPLACE X Series 147
3.5.6
3.5.6 Replacing the Complete Lever/Toggle [03013445-xx]
Replacing the Complete Lever/Toggle [03013445-xx]
Removal/installation
3.5.7
3.5.7 Installation and Height Adjustment of Nozzle Station (Description for Docking Unit [03015680-06] with 1-Wire-Hub)
Installation and Height Adjustment of Nozzle Station (Description for Docking Unit
[03015680-06] with 1-Wire-Hub)
1. Toggle
2. Fastening screw
► Loosen the screw (2) holding the toggle (1).
► Remove the toggle (1), insert a new one and fix this
with the fastening screw (2).
1
2
1. T-piece on component trolley feed device
► Disconnect the pneumatic hose from the COT insert.