00194440-10_SM_X-Series_Customer_en - 第192页
Service Work Modular PCB Conveyor System 3.6.22 Overview of the Electrical Co mponents 192 Service Manua l SIPLACE X Series 3.6.22.2 3 . 6 . 2 2 . 2 C o n v e y o r C o n v e r s io n B o a r d ( S in g le a n d D u a l …

Service Work
3.6.22 Overview of the Electrical Components Modular PCB Conveyor System
Service Manual SIPLACE X Series 191
Installation
See also
5.4.7 Readjusting the Holder for the Stopper and Proximity Switch (QC) [ ➙ 338]
3.6.22
3.6.22 Overview of the Electrical Components
Overview of the Electrical Components
3.6.22.1
3.6.22.1 Conveyor Edge Conversion Board [00359424-xx]
Conveyor Edge Conversion Board [00359424-xx]
Overview
► Fit the new stopper.
► Restore all electrical and pneumatic connections.
CAUTION!
If you have loosened or removed the holding fixture (1)
for the stopper and proximity switch during work, this will
need to be readjusted.
1. Conveyor edge conversion board
2. Cover
The conversion boards for the conveyor edges (1) are sit-
uated on the respective conveyor edges, under a cover
(2).
For terminal assignment details, please refer to the cur-
rent version of the circuit diagram folder.
1
2

Service Work
Modular PCB Conveyor System 3.6.22 Overview of the Electrical Components
192 Service Manual SIPLACE X Series
3.6.22.2
3.6.22.2 Conveyor Conversion Board (Single and Dual Conveyor) [00359425-xx]
Conveyor Conversion Board (Single and Dual Conveyor) [00359425-xx]
Overview
3.6.22.3
3.6.22.3 Conveyor Conversion Board (Quad Lane Conveyor) [03066716-xx]
Conveyor Conversion Board (Quad Lane Conveyor) [03066716-xx]
See also
3.6.17 Replacing the Conveyor Conversion Board [ ➙ 183]
1. Conveyor conversion board
2. Cover
The conveyor conversion board (1) is situated in the vi-
cinity of the intermediate conveyor, under the cover (2).
For terminal assignment details, please refer to the cur-
rent version of the circuit diagram folder.
1
2
Connection assignment for the assembly tub conversion
board
1. Conveyor conversion board
2. Cover
This board is located in the intermediate conveyor under
a cover.
For terminal assignment details, please refer to the cur-
rent version of the circuit diagram folder.

Service Work
3.6.22 Overview of the Electrical Components Modular PCB Conveyor System
Service Manual SIPLACE X Series 193
3.6.22.4
3.6.22.4 Lifting Table Conversion Board [00362766-xx]
Lifting Table Conversion Board [00362766-xx]
Overview
3.6.22.5
3.6.22.5 Conveyor Control TSP 301 [00370397-xx]
Conveyor Control TSP 301 [00370397-xx]
Overview
1. Lifting table conversion board
2. Cover
The lifting table conversion board (1) is situated on the
lifting table unit, under the cover (2).
For terminal assignment details, please refer to the cur-
rent version of the circuit diagram folder.
1
2
1. Conveyor Control TSP 301
2. Access to conveyor control
3. Transport direction
The TSP 301 conveyor control (1) is situated on the right
side of the middle section of the machine (2) (together
with the pneumatic unit). The conveyor control is secured
with a lockable door.
For terminal assignment details, please refer to the cur-
rent version of the circuit diagram folder for the relevant
machine.
NOTICE
MA data on station computer
The current MA data are saved on the TSP (conveyor control).
► The machine data for the conveyor is saved with the other data in the SW70x.
► SW 60x: Perform a backup of this data at the station computer, at C:\Srcma.
NOTICE
MA data on station computer
The current MA data are saved on the TSP (conveyor control).
► Perform backup of this data at the station computer, at C:\Srcma.
► When replacing the TSP (conveyor), this data can be then be recovered (via SITEST).