00194440-10_SM_X-Series_Customer_en - 第200页
Service Work X-Series COT Insert 3.7.6 Replacin g the Empty-Tape Duct Assembly [03021207- xx] 200 Service Manua l SIPLACE X Series 3.7.6 3 . 7 . 6 R e p la c in g t h e E m p t y - T a p e D u c t A s s e m b ly [ 0 3 0 …

Service Work
3.7.4 Voltage Supply 30V DC-DC Transformer [03020549-xx] X-Series COT Insert
Service Manual SIPLACE X Series 199
3.7.4
3.7.4 Voltage Supply 30V DC-DC Transformer [03020549-xx]
Voltage Supply 30V DC-DC Transformer [03020549-xx]
Overview
3.7.5
3.7.5 Replacing the Safety Switch [03019065-xx]
Replacing the Safety Switch [03019065-xx]
Overview
Removal/installation
1. Installation point of voltage supply
2. Power supply
3. Mounting plate
4. Transport direction
4
1
3
2
1. Security switch
The safety switch is installed at the locations in the COT
insert.
1
1. Security switch
2. Four fastening screws
3. Contact jack
► Unplug the connection cable.
► Loosen the four fastening screws (2) and then re-
move the safety switch (1).
► Fit the new safety switch.
► Move the changeover table into the COT insert and
check whether the changeover table can be moved
into the contact jack (3). Correct the position of the
safety switch, where necessary.
► Reconnect to the electricity supply.
3
2
1

Service Work
X-Series COT Insert 3.7.6 Replacing the Empty-Tape Duct Assembly [03021207-xx]
200 Service Manual SIPLACE X Series
3.7.6
3.7.6 Replacing the Empty-Tape Duct Assembly [03021207-xx]
Replacing the Empty-Tape Duct Assembly [03021207-xx]
Removal/installation
3.7.7
3.7.7 Replacing the Control Valve [03003489-xx]
Replacing the Control Valve [03003489-xx]
Removal/installation
See also
3.7.1 Replacing the X-Series COT Insert [03015680-xx] [ ➙ 195]
1. COT insert assembly
2. Empty-tape duct assembly
3. Position of the sensors
► Mark the position of the sensors (3) (reed contacts)
and remove these from the reject container.
► Loosen the two screws (4) holding the empty-tape
duct assembly (2).
► Carefully lift the empty-tape duct (2) out of the COT
insert (1).
► Fit the sensors (reed contacts) for the reject contain-
er.
NOTICE!
These sensors are installed in different positions, accord-
ing to the configuration of the machine.
► Fit the empty-tape duct.
4
1
4
3
2
► Remove the complete COT insert from the machine
and place it on a suitable surface.
► Unplug the electricity and compressed air cables
from the control valve (1).
► Loosen the fastening screws and remove the control
valve (1).
► Install the new control valve (1).
► Reconnect to the electrical and compressed air sys-
tems.
► Fit the complete COT insert in the machine.
1

Service Work
3.7.8 Replacing the Baffles [03002191-xx] X-Series COT Insert
Service Manual SIPLACE X Series 201
3.7.8
3.7.8 Replacing the Baffles [03002191-xx]
Replacing the Baffles [03002191-xx]
Overview
Removal/installation
► Replace the individual baffles as described below:
► Loosen the four screws (5) fastening the "baffle, outside" on both side panels.
► Loosen the four screws(6) fastening the "baffle, inside" on both side panels.
► Loosen the two screws (7) fastening the baffle insert.
1. Empty-tape duct assembly
2. Baffles
1
2
1. Baffle outside
2. Baffle, inside
3. Baffle insert
4. Side panels
NOTICE!
Inner baffle
When using tape reels with deep pockets, you may need
to remove the inner (center) baffle (2). Refer to the oper-
ating instructions for the relevant SIPLACE machine.
All screws are accessible in the installed state. The baf-
fles can therefore be replaced inside the machine.
1
4
3
2
7
6
5
4
7