00194440-10_SM_X-Series_Customer_en - 第27页

Overview of the Modules 2.2.1 Axis Units Electrical System Service Manual SIPLACE X Series 27 2.2.1.3 2 . 2 . 1 . 3 A 3 6 4 - A x is C a r d s f o r X M a c h in e T y p e s a n d H e a d M o d u la r it y A364 - Axis Ca…

100%1 / 384
Overview of the Modules
Electrical System 2.2.1 Axis Units
26 Service Manual SIPLACE X Series
2.2.1.2
2.2.1.2 A363 - Axis Cards for X Machine Types and Head Modularity
A363 - Axis Cards for X Machine Types and Head Modularity
X4 Assembly 1 Adr. Assembly 2 Adr. Assembly 3 Adr. Assembly
4
Adr.
Placement area 1 Gantry 1 Gantry 4
Axis type/gantry X1 0 Z1_1 3 X4 6 Z4_1 9
Axis type/gantry Y1 1 DP1_1 4 Y4 7 DP4_1 10
Axis type/gantry S1
Z1_2
2Free
DP1_2
5S4
Z4_2
8Free
DP4_2
11
Placement area 2 Gantry 2 Gantry 3
Axis type/gantry X2 16 Z2_1 19 X3 22 Z3_1 25
Axis type/gantry Y2 17 DP2_1 20 Y3 23 DP3_1 26
Axis type/gantry S2
Z2_2
18 Free
DP2_2
21 S3
Z3_2
24 Free
DP3_2
27
X3 Assembly 1 Adr. Assembly 2 Adr. Assembly 3 Adr. Assembly
4
Adr.
Placement area 1 Gantry 1 Gantry 4
Axis type/gantry X1 0 Z1_1 3 X4 6 Z4_1 9
Axis type/gantry Y1 1 DP1_1 4 Y4 7 DP4_1 10
Axis type/gantry S1 2 Free 5 S4 8 Free 11
Placement area 2 Gantry 3
Axis type/gantry X3 22 Z3_1 25
Axis type/gantry Y3 23 DP3_1 26
Axis type/gantry S3
Z3_2
24 Free
DP3_2
27
X2 Assembly 1 Adr. Assembly 2 Adr. Assembly 3 Adr. Assembly
4
Adr.
Gantry 1 Gantry 2
Axis type/gantry X1 0 Z1_1 3 X2 6 Z2_1 9
Axis type/gantry Y1 1 DP1_1 4 Y2 7 DP2_1 10
Axis type/gantry S1
Z1_2
2Free
DP1_2
5S2
Z2_2
8Free
DP2_2
11
Overview of the Modules
2.2.1 Axis Units Electrical System
Service Manual SIPLACE X Series 27
2.2.1.3
2.2.1.3 A364 - Axis Cards for X Machine Types and Head Modularity
A364 - Axis Cards for X Machine Types and Head Modularity
X4 and X4I Assembly 1 Adr. Assembly 2 Adr. Assembly 3 Adr.
Placement area 1
Axis type/gantry X1 0 X4 4 DP1_1 8
Axis type/gantry Y1 1 Y4 5 Free
DP1_2
9
Axis type/gantry S1
Z1_2
2S4
Z4_2
6DP4_1 10
Axis type/gantry Z1_1 3 Z4_1 7 Free
DP4_2
11
Placement area 2
Axis type/gantry X2 16 X3 20 DP2_1 24
Axis type/gantry Y2 17 Y3 21 Free
DP2_2
25
Axis type/gantry S2
Z2_2
18 S3
Z3_2
22 DP3_1 26
Axis type/gantry Z2_1 19 Z3_1 23 Free
DP3_2
27
X3 Assembly 1 Adr. Assembly 2 Adr. Assembly 3 Adr.
Placement area 1
Axis type/gantry X1 0 X4 4 DP1_1 8
Axis type/gantry Y1 1 Y4 5 Free
DP1_2
9
Axis type/gantry S1
Z1_2
2S4
Z4_2
6DP4_1 10
Axis type/gantry Z1_1 3 Z4_1 7 Free
DP4_2
11
Placement area 2
Axis type/gantry 16 X3 20 24
Axis type/gantry 17 Y3 21 25
Axis type/gantry 18 S3
Z3_2
22 DP3_1 26
Axis type/gantry 19 Z3_1 23 Free
DP3_2
27
X2 Assembly 1 Adr. Assembly 2 Adr. Assembly 3 Adr.
Axis type/gantry X1 0 X3 4 DP1_1 8
Axis type/gantry Y1 1 Y3 5 Free
DP1_2
9
Axis type/gantry S1
Z1_2
2S3
Z3_2
6DP3_1 10
Axis type/gantry Z1_1 3 Z3_1 7 Free
DP3_2
11
Overview of the Modules
Electrical System 2.2.1 Axis Units
28 Service Manual SIPLACE X Series
2.2.1.4
2.2.1.4 Servo Amplifier TBS .. and SDS ...
Servo Amplifier TBS .. and SDS ...
Servo amplifier
The servo amplifiers of type TBS are used for the X/Y and star axes, while the SDS servo amplifier is
used for the Z and DP axes. SDS servo amplifiers can process voltages of up to 60 VDC or 120 VDC,
depending on the input.
These SDS and TBS servo amplifiers can be reset with the servo release switch on the axis controller
board.
All servos have been set to the maximum motor current of the connected drive. This means that the ser-
vo amplifiers need to be used on an axis-specific basis.
Measuring point MP7:
In the event of errors, voltages can be measured at analog output MP7 with the help of the measuring
device, to help you ascertain the cause of the error.
Overvoltage -1 V
Overcurrent -2 V
Overtemperature -3 V
Nominal current exceeded -4 V