00194440-10_SM_X-Series_Customer_en - 第273页

Settings 5.2.1 Checking the X Axis Dynamics Axis Control Service Manual SIPLACE X Series 273 5.2.1.3 5 . 2 . 1 . 3 C o m p a r is o n o f X A x is T r a v e l P r o f ile s f o r C & P 2 0 A , C P P a n d T w in H e …

100%1 / 384
Settings
Axis Control 5.2.1 Checking the X Axis Dynamics
272 Service Manual SIPLACE X Series
5.2.1.2
5.2.1.2 Measurement Setup with SAT Box and A364
Measurement Setup with SAT Box and A364
Measurement setup with SAT box
CAUTION
Checking the dynamics/troubleshooting
When checking the dynamics, it may be sufficient if you check the travel times and overshoot
behavior of the axis with the SIPLACE axis tester (SAT) display and the values in the settings
tables.
However, when checking for errors, you will need to use a suitable oscilloscope for the dynam-
ics analysis.
Settings
5.2.1 Checking the X Axis Dynamics Axis Control
Service Manual SIPLACE X Series 273
5.2.1.3
5.2.1.3 Comparison of X Axis Travel Profiles for C&P20A, CPP and TwinHead
Comparison of X Axis Travel Profiles for C&P20A, CPP and TwinHead
Signal path at 15000 digit travel range of X axis for different head configurations
1. Axis start
2. The end position signal is triggered at different times, depending on the axis records for the 3 head
configurations.
CAUTION
Maximum deviation of position
The maximum deviation of position depends on the placement head:
C&P20A: 12 µm (digit)
CPP: 10 μm (digit)
TwinHead: 5 μm (digit)
Settings
Axis Control 5.2.1 Checking the X Axis Dynamics
274 Service Manual SIPLACE X Series
5.2.1.4
5.2.1.4 X Axis Travel Time Table, According to Placement Heads
X Axis Travel Time Table, According to Placement Heads
Travel times for X gantry axis with the various head configurations
* C&P: for SW 603.xx, the X axis target times are approx. 5 ms shorter than those specified above.
Distance /
digit
X gantry axis with C&P20 X gantry axis with DLM2
(C&P6, C&P12)
X gantry axis with TwinHead
Target time /
ms*
Tolerance /
ms
Target time /
ms*
Tolerance /
ms
Target time /
ms
Tolerance /
ms
50018+/-526+/-525+/-5
1000 20 +/-5 29 +/-5 28 +/-5
2000 24 +/-5 35 +/-5 34 +/-5
5000 31 +/-5 47 +/-5 41 +/-5
15000 47 +/-5 58 +/-5 54 +/-5
20000 53 +/-5 64 +/-5 59 +/-5
50000 79 +/-10 87 +/-10 87 +/-10
100000 108 +/-10 126 +/-10 125 +/-10
200000 151 +/-10 174 +/-10 170 +/-10
300000 190 +/-15 213 +/-15 209 +/-15