00194440-10_SM_X-Series_Customer_en - 第284页

Settings Axis Control 5.2.3 C&P6/12 284 Service Manua l SIPLACE X Series Signal Example with the Vnom. Output SITEST: ► Select C&P heads ==> Select head ==> Axis functions ==> Select the star axis ==>…

100%1 / 384
Settings
5.2.3 C&P6/12 Axis Control
Service Manual SIPLACE X Series 283
Measurement Setup with SAT Box and A364
Measurement setup with SAT box
Settings
Axis Control 5.2.3 C&P6/12
284 Service Manual SIPLACE X Series
Signal Example with the Vnom. Output
SITEST:
Select C&P heads ==> Select head ==> Axis functions
==> Select the star axis ==> Star continuous operation ==> Entry: waiting period 500 ms
==> Accept.
Press the START button if required.
C&P12 - star axis diagram
Dynamic signals for star axis, in example of C&P6
The star axis dynamics are checked in the permanent
star step mode. A motor phase current is emitted at the
Vnominal output of the axis test box.(control signal 1).
The uncommutated current setpoint signal (signal 3)
shows increased friction values for the axis.
1. Control signal (axis test box V nom.)
2. Uncommutated current signal at axis adapter
3. Deviation of position
4. End signal
Star axis travel curves for C&P12
1. Current target value: 2 V/Div
2. Position deviation: 500 mV/Div
3. End signal
Time basis: 10ms/Div
1 step = 30000 digits = 30 degrees
Settings
5.2.3 C&P6/12 Axis Control
Service Manual SIPLACE X Series 285
C&P6 - star axis diagram
Star axis travel curves for C&P6
1. Current target value: 2 V/Div
2. Position deviation: 500 mV/Div
3. End signal
Time basis: 10ms/Div
Step: 60000 digits = 60 degrees
NOTICE
Dynamics
If the dynamics are significantly slower, check the friction blocks on the star and the installation
of the star in the drive's magnetic neutral position.