00194440-10_SM_X-Series_Customer_en - 第311页
Settings 5.2.5 TwinHead Axis Control Service Manual SIPLACE X Series 311 Checking the Force Sensor Function SITEST ► Select TwinHead ==> Axis functions ► Position th e gantry ov er the convey or edge. == > Select s…

Settings
Axis Control 5.2.5 TwinHead
310 Service Manual SIPLACE X Series
Travel curves for TwinHead Z axis in free space (down
-
wards)
TwinHead - Z axis in free space (downwards)
1. Torque-forming motor current 500 mV/20 ms
2. Position deviation 500 mV/20 ms
3. Positioning time approx. 75 ms
TwinHead - Z axis in free space (upwards)
1. Position deviation 500 mV/20 ms
2. Torque-forming motor current 500 mV/20 ms
3. Positioning time approx. 75 ms
TwinHead - Z axis in free space (downwards)
Target position: 54200 digits); camera focus range
Positioning type: absolute waiting period: 100 ms
1. Torque-forming motor current 500 mV/20 ms
2. Position deviation 500 mV/20 ms
3. Positioning time approx. 57 ms

Settings
5.2.5 TwinHead Axis Control
Service Manual SIPLACE X Series 311
Checking the Force Sensor Function
SITEST
► Select TwinHead ==> Axis functions
► Position the gantry over the conveyor edge. ==> Select segment
==> Select Z axis ==> Axis dynamics ==> Edit and accept values:
Travel profile down: 5 (2 N), 7 (5 N and 10 N), 25 (15 N) travel profile up: always 2
Waiting period up/down: 500 ms
Force down: 2, 5, 10, or 15 N
► Press the START button if required.
Evaluation of oscillograms:
The placement force is calculated from several factors, such as the Z axis weight, a motor constant, lin-
ear guidance friction and the torque-forming motor current. The spring pretension and force sensor val-
ues also influence the placement force.
This means that, if these values are not entered correctly, it will not be possible to reach the set place-
ment forces.
By using the oscillograms, the torque-forming motor current value during the end position signal can be
used as a reference point for the placement force.
If the placement force is 5 N, the oscillogram should show a torque-forming motor current value (meas-
ured against GND) of near 500 mV, after the end position signal (1 V = 1 A). The factors specified above
are not considered here, leading to relatively high tolerances.
TwinHead - Z axis in free space (upwards)
1. Position deviation 500 mV/20 ms
2. Torque-forming motor current 500 mV/20 ms
3. Positioning time approx. 57 ms
TwinHead - Z axis with 1N placement force (downwards)
1. Torque-forming motor current 500 mV/20 ms
2. Amplitude approx. 100 mV
3. Position deviation 5 V/20 ms
4. Positioning time approx. 78 ms

Settings
Axis Control 5.2.5 TwinHead
312 Service Manual SIPLACE X Series
TwinHead - Z axis with 2N placement force (downwards)
1. Torque-forming motor current 500 mV/20 ms
2. Amplitude approx. 200 mV
3. Position deviation 5 V/20 ms
4. Positioning time approx. 78 ms
TwinHead - Z axis with 5N placement force (downwards)
1. Position deviation 5 V/20 ms
2. Torque-forming motor current 500 mV/20 ms
3. Amplitude approx. 500 mV
4. Positioning time approx. 78 ms
TwinHead - Z axis with 10N placement force (down-
wards)
1. Torque-forming motor current 500 mV/20 ms
2. Amplitude approx. 1000 mV
3. Position deviation 5 V/20 ms
4. Positioning time approx. 65 ms