00194440-10_SM_X-Series_Customer_en - 第317页

Settings 5.3.1 Setting the Height of the Nozzle Changer for the C&P20A No zzle Changer Setting Service Manual SIPLACE X Series 317 5.3.1.1 5 . 3 . 1 . 1 N o z z le R e je c t U n it Nozzle Reject Unit The C&P20A …

100%1 / 384
Settings
Nozzle Changer Setting 5.3.1 Setting the Height of the Nozzle Changer for the C&P20A
316 Service Manual SIPLACE X Series
5.3
5.3 Nozzle Changer Setting
Nozzle Changer Setting
5.3.1
5.3.1 Setting the Height of the Nozzle Changer for the C&P20A
Setting the Height of the Nozzle Changer for the C&P20A
Parts, equipment and tools
Measuring scale
NC shim plate [03021079-xx]
Overview
Setting
Setting the nozzle changer for C&P20A
1. Measuring scale
2. Top edge of the X axis lower linear guide
3. Fitting surface for nozzle changer
In order to guarantee the safety gap between the head
(component sensor) and nozzle changer, the contact sur-
face of the nozzle changer on the docking unit is set to a
distance of 150.0 mm +/-0.2 mm to the X axis linear guid-
ance, with a measuring scale. The height of the fitting sur-
face on the docking unit is adjusted with the help of shim
rings. The nozzle changer can then be fitted.
1. Measuring scale
2. Top edge of the X axis lower linear guide
3. Values to be set (150 +/- 0.2 mm)
4. Nozzle changer contact surface
During the following inside measurement, make sure
that the tip of the measuring scale does not tough the
magnetic strip, as this might scratch it!
Position the measuring scale (1) on the top edge of
the X axis lower linear guide (2) and measure the dis-
tance to the nozzle changer contact surface (4).
Hold the measuring scale vertically (1).
The setting value (4) is 150 +/-0.2 mm.
Add or remove shims as required.
Repeat this measurement on the inside of the gantry
(5).
Calibrate the position of the nozzle changer.
Settings
5.3.1 Setting the Height of the Nozzle Changer for the C&P20A Nozzle Changer Setting
Service Manual SIPLACE X Series 317
5.3.1.1
5.3.1.1 Nozzle Reject Unit
Nozzle Reject Unit
The C&P20A reject unit is equipped with a device for
checking the seat of the nozzles on the segments.
The height of the nozzle reject unit must be set to 140.0
+\-0.3 mm. Measurement follows the same procedure as
that for the nozzle changer (see "5.3.1 Setting the Height
of the Nozzle Changer for the C&P20A" [ 316]).
1. Check nozzle seat
2. Nozzle reject
Settings
Nozzle Changer Setting 5.3.2 Jumpers on the Nozzle Changer
318 Service Manual SIPLACE X Series
5.3.2
5.3.2 Jumpers on the Nozzle Changer
Jumpers on the Nozzle Changer
The jumper X10 needs to be set at the following nozzle changers:
Nozzle changer basic structure CPx/all assembly - short [03103649-xx]
Nozzle changer basic structure CPx/all assembly - long [03103514-xx]
Overview
Setting
Set the correct value for your head type and software.
Nozzle Changer CP20P - Jumper X10
Jumper X10
See also
6.6.2 Nozzle Changer Main Board C&P20P [03107652-xx] [ ➙ 380]
1. Jumper X10
NOTICE
Before installation
Due to the design, this setting must be performed before installation in the machine.
Head Jumper position
SW <= 706.x SW >= 707.x
CPx, DLM 1-2 1-2 or 2-3
C&P20 P --- 2-3 (factory settings)