00194440-10_SM_X-Series_Customer_en - 第335页

Settings 5.4.6 Board Clamping Functions Conveyor Settings Service Manual SIPLACE X Series 335 5.4.6.2 5 . 4 . 6 . 2 S e t t in g t h e B o a r d C la m p in g Setting the Board Clamping ► To check whether the board clamp…

100%1 / 384
Settings
Conveyor Settings 5.4.6 Board Clamping Functions
334 Service Manual SIPLACE X Series
5.4.6.1
5.4.6.1 Setting Board Clamping
Setting Board Clamping
Setting actuator
1. Setting Gauge for Actuator [03049740-xx]
2. Actuator
3. Drilling, for fixing the actuator screws, when the
gauge is fitted
If the conveyor control issues the error Clamping error
conveyor, you need to check the distance from the lifting
table actuator to the upper edge of the conveyor belt.
Use the setting gauge to check and set the actuator. The
distance from the clamping actuator (lifting table) to the
top edge of the belt should be 94.0 mm at all four contact
points. (see diagram)
Settings
5.4.6 Board Clamping Functions Conveyor Settings
Service Manual SIPLACE X Series 335
5.4.6.2
5.4.6.2 Setting the Board Clamping
Setting the Board Clamping
To check whether the board clamping is functioning properly, clamp a board with the lifting table.
Then check whether the board is clamped tightly on the side.
Tools
Setting (single and dual conveyor)
The terminal strip may need to be modified, depending on the machine type. As the S27 only has a
maximum clamping area of 74 mm, the terminal strip needs to be fitted on the correct side. The ter-
minal strip for X series, HS-60 and D series machines needs to be set to 94 mm. Fit the terminal
strip accordingly on the gauge.
The gauge is inserted between the actuator and the clamp.
The actuator can now be released, moved down and then tightened again through the holes provid-
ed.
NOTICE
Only in the event of problems
This setting should only be made if there are problems with the clamping.
The clamping function is set with the "Adjust gauge actu-
ator cpl" [03049740-xx].
Terminal strip for S27, HS-60, HF, X2, X3, X4
[03049739-xx]
Long terminal strip for X4I [03076698-xx]
Settings
Conveyor Settings 5.4.6 Board Clamping Functions
336 Service Manual SIPLACE X Series
Quad lane conveyor settings
For initial setting, follow the procedure used for the single and dual conveyors (see above). Make
sure that the long terminal strip [03076698-xx] is fitted on the 94 mm side of the "setting gauge ac-
tuator assembly".
As two boards are clamped with the same lifting table, you need to check the clamping play for each
of the single conveyors.
The clamping actuators are delivered with a basic setting of 94.2 mm to the top edge of the conveyor
belt.
If problems occur during board clamping (board partially or fully loose), you will need to reset the
clamp.
The cause of this problem is that there are a total of six actuators on three conveyor edges. If these
are not set accurately enough (they do not form a level), up to three actuators might have been set
incorrectly. These then need to be adjusted.
(1) Conveyor belt play on the lower edge of the
clamp
(2) Distance 94.2 mm.