Settings Conveyor Settings 5.4.7 Readjusting the Holder for t he Stopper a nd Proximity Switch (QC) 338 Service Manua l SIPLACE X Series 5.4.7 5 . 4 . 7 R e a d ju s t in g t h e H o ld e r f o r t h e S t o p p e r a n …

100%1 / 384
Settings
5.4.6 Board Clamping Functions Conveyor Settings
Service Manual SIPLACE X Series 337
Procedure
A) Checking the clamping play:
Move the lifting table upwards, without the board.
With the aid of a 0.1 mm feeler gauge, check the gap between the conveyor belt and the clamp (see
graphic above).
If the gap is larger than 0.1 mm, the distance determined between the belt and clamping edge on the
actuator will need to be reset.
To do this, you need to add the current distance between the actuator and the clamping plate to the
distance between the belt and the clamping edge!
Move the lifting table down again.
B) Setting the play on the actuator:
Disable the clamp and move the lifting table down.
Measure the play between the actuator and the side edge with a feeler gauge.
Loosen the actuator screws.
Set the distance again with the help of a feeler gauge.
Add the play for the clamp to the play for the actuator.
Tighten the actuator screws again.
You now need to recheck the gap between the conveyor belt and the clamp when the lifting table
has moved up. (see above)
If a problem occurs during board clamping, recheck this setting again. We recommend that you
check this setting every three months. When cleaning the machine, always make sure that you re-
move all components from the conveyor belt.
NOTICE
Play between the terminal strip and the upper edge of the conveyor belt
The play between the terminal strip and the upper edge of the conveyor belt may not be more
than 0.1 mm.
1. Actuator screwed fixtures
2. Measuring the play with the feeler gauge
Settings
Conveyor Settings 5.4.7 Readjusting the Holder for the Stopper and Proximity Switch (QC)
338 Service Manual SIPLACE X Series
5.4.7
5.4.7 Readjusting the Holder for the Stopper and Proximity Switch (QC)
Readjusting the Holder for the Stopper and Proximity Switch (QC)
If the fixture rail for the stopper and proximity switch is loosened or dismantled, this will need to be read-
justed.
Tools
Standard tool
Gauge for Stopper Setting [03067221-xx]
Performing the setting
Position of the conveyor edges with setting gauge.
1. Distance between the conveyor edges for fitting the
setting gauge
When dismantling the belt guidance, make sure that
the slide is secured.
Set the conveyor so that the conveyor edges are not
against one another.
Dismantling the clamping and distance rail.
Loosen the screws (1) and dismantle the clamping
rail and the distance rail of the conveyor edge.
Settings
5.4.8 Lifting Table Functions Conveyor Settings
Service Manual SIPLACE X Series 339
5.4.8
5.4.8 Lifting Table Functions
Lifting Table Functions
Lifting table up function
Requirements for detecting that the lifting table is up:
30-35 pulses from the incremental disc
Check performed by software (see "5.4.6 Board Clamping Functions" [ 333])
Dynamic response for board clamping of approx. 500 ms
Lifting table down function
Requirements for detecting that the lifting table is down:
30-35 pulses from the incremental disc
Proximity switch on the lifting table cylinder
Dynamic response for board release of approx. 480 ms
Fitting the stopper unit on the bracket with the help of the
setting gauge
Position the gauge on the pins. Lift the holder and
align it to the setting gauge (in X direction and height).
Then dismantle the setting gauge and fit the distance
and clamping rail.
Lifting table unit
1. Actuator
2. Lock nut damper
3. Fastening screws for mounting block
4. Damping unit
5. 3/5 way solenoid valve mounted on lifting table drive
cylinder
6. Fork-type light barriers / incremental disk