00194440-10_SM_X-Series_Customer_en - 第378页

Description of the Circuit Boards COT inse rt 6.5.1 Connecting assy FCU [03059783- xx] 378 Service Manua l SIPLACE X Series 6.5 6 . 5 C O T in s e r t COT insert 6.5.1 6 . 5 . 1 C o n n e c t in g a s s y F C U [ 0 3 0 5…

100%1 / 384
Description of the Circuit Boards
6.4.2 Control Unit on Cutter (CAN Nodes) Cutter
Service Manual SIPLACE X Series 377
6.4.2
6.4.2 Control Unit on Cutter (CAN Nodes)
Control Unit on Cutter (CAN Nodes)
With the CAN node module, a new controller [03052927-xx] has been developed for the SIPLACE X4I,
HF, D3 and X series machines. This controls both the cutter and the nozzle changer of the respective
location. If this control unit is installed in older machines, you will also need to use the relevant CAN bus
address jumper for your machine's installation site.
Description of CAN node NC tape cutter module
This board is backwards compatible to the old tape cutter board. It can be used at X, HF and D series
machines.
The CAN processor decides which functions need to be checked at the individual locations, depending
on the cables connected and the type of DIP switched set.
DIP switch group S3 - overview
1)
Not all gantries may be available, depending on the machine type.
2)
Even if there is no nozzle changer installed and only the tape cutter needs to be controlled, this switch
still needs to be set to OFF for the reject bin query and the reject station.
X series machine with CAN node
The cable of the machine (cable harness machine) has to be by-passed as shown in the list:
*112: Gantry 1: 10/11/12 by-passed
*122: Gantry 2: 11/12 by-passed
*132: Gantry 3: 10/12 by-passed
*142: Gantry 4: not by-passed
CAN node NC tape cutter module
1. X1 – Energy supply with automatic CAN ID
2. X2 – Energy supply, tape cutter +24 V/+5 V
3. X3 – Reject container (nozzles, components)
4. X4 – CAN bus connection
5. X5 – Energy supply to valve (left)
6. X6 – Energy supply to valve (right)
7. X7 – Proximity switch for stroke cylinder out (left)
8. X8 – Proximity switch for stroke cylinder in (left)
9. X9 – Proximity switch for stroke cylinder out (right)
10. X10 – Proximity switch for stroke cylinder in (right)
11. X11– Test connector, tape cutter
12. X12 – Compressed air valve (additional pneumatic
unit for rejecting components)
13. X13 – Nozzle changer, row 1
14. X14 – Nozzle changer, row 2
15. DIP switch group S3 (see below)
DIP
switch
DIP switch meaning
1ON: Setting the CAN ID via DIP switch 2 and 3 – OFF: Cable Select
2 CAN - ID 0
ON: Gantry 1
1)
ON
OFF: Gantry 2
1)
ON
ON: Gantry 3
1)
OFF
OFF: Gantry 4
1)
OFF: Cable se-
lect
3 CAN - ID 1
4
ON: Only tape cutter – OFF: Nozzle changer and tape cutter
2)
5ON: Module in reset-modeOFF: Module in standard mode
Description of the Circuit Boards
COT insert 6.5.1 Connecting assy FCU [03059783-xx]
378 Service Manual SIPLACE X Series
6.5
6.5 COT insert
COT insert
6.5.1
6.5.1 Connecting assy FCU [03059783-xx]
Connecting assy FCU [03059783-xx]
03059783-04
LED (test mode for reject box switched off – S2.1 ON) [03059783-04]
LED (test mode for reject box switched on – S2.1 OFF) [03059783-04]
Button S1 [03059783-04]
Dip switch S2 [03059783-04]
LED Color Status Signal name Description
H1, H2, H3, H4 GN Sequential shift
light
LED1, 2, 3, 4 FCU OK
H1, H2, H3, H4 GN ON LED1, 2, 3, 4 eSW application missing
H1, H2, H3, H4 GN Flashing LED1, 2, 3, 4 FCU error, reboot place-
ment machine or replace
FCU
LED Color Status Signal name Description
H1 or H2 or H3 or
H4
GN Flashes LED1 or 2 or 3 or
4
No sensor connected for
reject box 1 or 2 or 3 or 4
H1 or H2 or H3 or
H4
GN OFF LED1 or 2 or 3 or
4
Sensor for reject boxes 1 or
2 or 3 or 4 connected, but
no reject box inserted
H1 or H2 or H3 or
H4
GN ON LED1 or 2 or 3 or
4
Sensor for reject boxes 1 or
2 or 3 or 4 connected, but
no reject box inserted
Buttons Status Function Description
S1 OFF RESET When pressed
Switch Status Signal name Description
S2.1 ON/OFF FCU_ENV3 ON: test mode for reject box switched off
OFF: test mode for reject box switched on
S2.2 OFF FCU_ENV2 40-fold FCU
S2.3 ON/OFF FCU_ENV1 ON: without insert control, with virtual button
OFF: with insert control, without virtual button
S2.4 ON/OFF FCU_ENV0 ON: with tape cutter and with nozzle changer
functionality
OFF: without tape cutter and without nozzle
changer functionality
Description of the Circuit Boards
6.6.1 NC main board CPx [03069324-xx] Nozzle Changers
Service Manual SIPLACE X Series 379
6.6
6.6 Nozzle Changers
Nozzle Changers
6.6.1
6.6.1 NC main board CPx [03069324-xx]
NC main board CPx [03069324-xx]
03069324-02
LED [03069324-02]
LED Color Status Signal name Description
H1 GN ON LED_Magazines_OK Magazines inserted properly
H2 GN ON LED_LB_OPENED Actuator light barrier "open"
H3 GN ON LED_LB_CLOSED Actuator light barrier "closed"
H4 GN ON LED_FPGA_OK FPGA has been loaded and is ready for op-
eration
H5 GN ON SWITCH_VALVE Valve voltage of +24V present
H6 GN ON P3V3 Logic voltage +3.3V present
H7 RD ON FPGA_TEST_6 Internal FPGA status 1
H8 RD ON FPGA_TEST_2 Internal FPGA status 2
H9 RD ON FPGA_TEST_4 Internal FPGA status 3
H10 RD ON FPGA_TEST_1 Internal FPGA status 4
H11 RD ON FPGA_TEST_3 Internal FPGA status 5
H12 RD ON FPGA_TEST_5 Internal FPGA status 6