00194440-10_SM_X-Series_Customer_en - 第91页

Service Work 3.3.4 Replacing the End Positi on / Reference Proximity Switch f or the Y Axis [0300410 6-xx] Gantries Service Manual SIPLACE X Series 91 ► Rep lace the re levant proxim i ty switch and install the proximity…

100%1 / 384
Service Work
Gantries 3.3.4 Replacing the End Position / Reference Proximity Switch for the Y Axis
90 Service Manual SIPLACE X Series
3.3.4
3.3.4 Replacing the End Position / Reference Proximity Switch for the Y Axis [03004106-xx]
Replacing the End Position / Reference Proximity Switch for the Y Axis [03004106-xx]
Parts
Y axis end position proximity switch [03004106-xx]
Reference point proximity switch for the Y axis [03004107-xx]
Removal/Installation
NOTICE
Only for machines with axis card A363
These proximity switches are not needed for machines using the A364 axis card (from X-Series
MA No. B-337 and X4I).
The end position/reference proximity switch function is included in the A364 axis card.
CAUTION
Use the heat-shrinkable sleeve for the cable duct
The proximity switch cables are fastened to the gantry with a heat-shrinkable sleeve so that
they will not rub or come loose during travel. Try to pull the proximity switch cable through this
sleeve so that you can reuse it. If this is not possible, you will need to slide over a new heat-
shrinkable sleeve.
1. Position of end position proximity switch Y axis and
reference point proximity switch Y axis.
This sensor has no longer been fitted since the intro-
duction of the axis card 364 (from ma. no. 357).
2. End position proximity switch mount
Unplug the press-fit connections for the end position
proximity switch (1) or reference proximity switch (1)
from the gantry interface.
Unthread the connection cable as far as the proximity
switches.
Loosen the screw fastening the proximity switch
mount (2).
Service Work
3.3.4 Replacing the End Position / Reference Proximity Switch for the Y Axis [03004106-xx] Gantries
Service Manual SIPLACE X Series 91
Replace the relevant proximity switch and install the
proximity switch mount with the proximity switches.
Make sure there is a gap of 0.4 mm between the prox-
imity switches and the trigger bar. Use the corre-
sponding thickness gauge (plastic).
Reconnect to the electricity supply.
Make sure that the cables do not rub against any-
thing. Pull the cable through the heat-shrinkable
sleeve or attach a new sleeve.
CAUTION
Check how the cables are run!
Make sure that the axes can be moved without damaging the cables.
Service Work
Gantries 3.3.5 Replacing the Cooling Tubes for the Y Axis Motor Cooling System
92 Service Manual SIPLACE X Series
3.3.5
3.3.5 Replacing the Cooling Tubes for the Y Axis Motor Cooling System [03003704 -xx]
Replacing the Cooling Tubes for the Y Axis Motor Cooling System [03003704 -xx]
General Notes
When only one gantry is installed, there are two different cooling tube sets. Make sure that the cooling
tubes are always replaced with ones of the same type: replace black tubes with black tubes and white
tubes with white tubes.
Parts
Cooling air set (black) [03003704-xx]
Cooling air set (white) [03030955-xx]
Overview
General installation
1. Cooling tube connections on the Y axis motor
2. Trailing cable console
3. Trailing cable profile
4. Cooling tubes
Depending on the trailing cable used, the two tubes
(1) may need to be shortened to the required length:
⇨ Trailing cable for 1 gantry = 1011 mm
⇨ Trailing cable for 2 gantries (1/3) = 921 mm
⇨ Trailing cable for 2 gantries (2/4) = 1086 mm
CAUTION!
Both tubes must be exactly the same length.
To be on the safe side, compare the length of the new
tubes with the length of the old tubes.
Cover existing stationary cameras with suitable ma-
terial to prevent contamination.