Service Work Gantries 3.3.5 Replacing the Cooling Tubes for the Y Axis Motor Cooling System 92 Service Manual SIPLACE X Series 3.3.5 3 . 3 . 5 R e p la c in g t h e C o o lin g T u b e s f o r t h e Y A x is M o t o r C …

100%1 / 384
Service Work
3.3.4 Replacing the End Position / Reference Proximity Switch for the Y Axis [03004106-xx] Gantries
Service Manual SIPLACE X Series 91
Replace the relevant proximity switch and install the
proximity switch mount with the proximity switches.
Make sure there is a gap of 0.4 mm between the prox-
imity switches and the trigger bar. Use the corre-
sponding thickness gauge (plastic).
Reconnect to the electricity supply.
Make sure that the cables do not rub against any-
thing. Pull the cable through the heat-shrinkable
sleeve or attach a new sleeve.
CAUTION
Check how the cables are run!
Make sure that the axes can be moved without damaging the cables.
Service Work
Gantries 3.3.5 Replacing the Cooling Tubes for the Y Axis Motor Cooling System
92 Service Manual SIPLACE X Series
3.3.5
3.3.5 Replacing the Cooling Tubes for the Y Axis Motor Cooling System [03003704 -xx]
Replacing the Cooling Tubes for the Y Axis Motor Cooling System [03003704 -xx]
General Notes
When only one gantry is installed, there are two different cooling tube sets. Make sure that the cooling
tubes are always replaced with ones of the same type: replace black tubes with black tubes and white
tubes with white tubes.
Parts
Cooling air set (black) [03003704-xx]
Cooling air set (white) [03030955-xx]
Overview
General installation
1. Cooling tube connections on the Y axis motor
2. Trailing cable console
3. Trailing cable profile
4. Cooling tubes
Depending on the trailing cable used, the two tubes
(1) may need to be shortened to the required length:
⇨ Trailing cable for 1 gantry = 1011 mm
⇨ Trailing cable for 2 gantries (1/3) = 921 mm
⇨ Trailing cable for 2 gantries (2/4) = 1086 mm
CAUTION!
Both tubes must be exactly the same length.
To be on the safe side, compare the length of the new
tubes with the length of the old tubes.
Cover existing stationary cameras with suitable ma-
terial to prevent contamination.
Service Work
3.3.5 Replacing the Cooling Tubes for the Y Axis Motor Cooling System [03003704 -xx] Gantries
Service Manual SIPLACE X Series 93
Use cable ties to fix the two tubes at the top.
Push the two cooling tube fixtures (3) onto the tubes.
For easier fitting, you can apply a little grease (Molykote) to the spacer of the black cooling tube.
Fit the two cooling tube fixtures (3) to position 5 (4) and 10 (5) in the trailing cable profile (6).
Installation of black and white cooling tubes
Observe the following for white cooling tubes!
CAUTION
Observe the preferred direction during installation!
Observe the curvature (preferred direction) of the tube.
Push the two cooling tube fixtures (1) onto the tubes
(2).
Fit the two cooling tube fixtures (1) to position 5 (3)
and 10 (4) in the trailing cable profile (5) - from below.
Note: For black cooling air tube only:
Carefully lubricate the cooling tubes with a small
amount of grease (Molykote).
Push the gantry into the first end position (the long
part of the trailing cable is at the top).
Check how the tubes are run in the trailing cable pro-
file. Make sure the tube is neither too short nor too
long - depending on the relevant travel range. The
following photos should help you to assess how well
the tubes have been run.
Insert the two support rollers into the holes (1) provid-
ed in the power track chain.
Push the gantry into the first end position (the long
part of the trailing cable is at the top).
CAUTION!
Do not lubricate white cooling tubes!
Do not apply grease to the white tubes.
Check how the tubes are run in the trailing cable pro-
file. Make sure the tube is neither too short nor too
long - depending on the relevant travel range. The
following photos should help you to assess how well