A-1
Appendix
1. Specifications
1.1 Air regulator unit
The air regulator for controlling the air pressure to the pneumatic units of the machine is located behind the
front lower left panel. A digital pressure gauge is provided on the front left of the machine.
Air pressure regulator and pressure gauge
Air supply/shutoff
valve
Air release valve
(for tape cutter)
Air pressure
regulator
Air pressure setting for machine
Pressure-drop detection level
53A00-L1-00
n
Supply air pressure
This is the pressure of the source air supplied to the machine. Before setting the air pressure with the air regulator, make
sure that this supply air pressure is in the following optimal range.
0.45MPa to 0.7MPa
n
Digital pressure gauge
Shows the supply air pressure (upper reading) and pressure-drop detection level (lower reading). A normal pressure value
is shown in green, and a pressure value lower than the pressure-drop detection level is shown in red.
n
Air pressure setting and pressure-drop detection level
Air pressure setting for machine (upper reading) : 0.40MPa to 0.41MPa
Pressure-drop detection level (lower reading) : 0.33MPa
n
Air supply/shutoff switch
Turning this valve to the right shuts off air supply and also discharges the air remaining in the air path.
n
Air release valve (for tape cutter)
Turning this valve to the right shuts off air supply to the tape cutter and also discharges the air remaining in the air path.
n
Source air connector
Prepare an air hose with an inner diameter of at least 8mm having a 40SH socket (Nitto Koki, or equivalent), and connect
it to this connector. Use dry, clean air passed through an air filter.

A-2
Appendix
1.2 Power connection terminals
The power connection terminals are located inside the lower right panel on the front of the machine. Connect
the power cable leads as shown below to the L1, L2, L3 and ground terminal (PE) on the power terminal block.
n
Power supply specifications
Model name Power Frequency Power capacity
YS100 3-phase AC 200/208/220/240/380/400/416V (±10%) 50/60Hz 5.2kVA
Power input terminals
(L1, L2, L3) and ground terminal
Main breaker
Power connection terminals
53A01-L1-00
Fork-tongue crimp terminal
Power cable example
L1
L2
L3
PE
L=100mm
Ring-tongue crimp terminal
53A02-L1-00
c
CAUTION
Use a power cable whose conductor cross-section area is greater than 2.5mm
2
.
w
WARNING
TO AVOID THE RISK OF ELECTRICAL SHOCK, MAKE SURE THAT THE POWER SOURCE IS OFF BEFORE CONNECTING THE
POWER CABLE. ALSO MAKE SURE THAT THE GROUND CABLE IS SECURELY CONNECTED TO THE MACHINE.