00191171-01 - 第36页
Offset calib ration system for SIPLACE 80 S15 / S20 / F3 / F4 Oper ating M anual Edition 01/ 98 Page 36 of 47 Entry in REAL.MA: \ Kameradaten \ \ Kamerabeschreibung 1. Kamera \ ..... \ Kamerabeschreibung 2. Kamera \ ....…

Operating Manual Offset calibration system for SIPLACE 80 S15 / S20 / F3 / F4
Edition 01/98
Page 35 of 47
Gantry 2
The PCB camera offset must be altered in REAL.MA. The correction values are entered in the machine
data in
µ
m!
New Kamera_Offset _X = Old Kamera_Offset_X + Arithmetic mean
New Kamera_Offset _Y = Old Kamera_Offset_Y + Arithmetic mean
Example:
Arithmetic mean: x = -60
µ
m
Old camera offset X: -1780
µ
m
New camera offset X: -1780
µ
m + (-60
µ
m) = -1840
µ
m
Arithmetic mean: y = 50
µ
m
Old camera offset Y: -79620
µ
m
New camera offset Y: -79620
µ
m + 50
µ
m = -79570
µ
m

Offset calibration system for SIPLACE 80 S15 / S20 / F3 / F4 Operating Manual
Edition 01/98
Page 36 of 47
Entry in REAL.MA:
\ Kameradaten \
\ Kamerabeschreibung 1. Kamera \
.....
\ Kamerabeschreibung 2. Kamera \
.....
\ **Kamera_Offset_X** \ -1840
\ **Kamera_Offset_Y** \ -79570
Gantry 1
The zero point correction must be altered in REAL.MA. The correction values are entered in the ma-
chine data in digit!
New Nullpunktkorrektur X = Old Nullpunktkorrektur X + Arithmetic mean
New Nullpunktkorrektur Y = Old Nullpunktkorrektur Y + Arithmetic mean
Example:
Arithmetic mean: x = -60
µ
m
Old zero point correction: x = -291235 digit
Conversion from
µ
m to digit: 50
µ
m / 2.5 = 20 digit (Conversion factor of the glass scale)
New zero point correction: x = -291235 digit + 20 digit = -291215 digit
Arithmetic mean: y = -75
µ
m
Old zero point correction: y = -616880 digit
Conversion from
µ
m to digit: -75
µ
m / 2.5 = -30 digit
New zero point correction: y = -616880 digit + (-30 digit) = -616910 digit

Operating Manual Offset calibration system for SIPLACE 80 S15 / S20 / F3 / F4
Edition 01/98
Page 37 of 47
Entry in REAL.MA:
\ Achsdaten \
\ X_Achsdaten \
\ Achsparameter 2 \
.....
\ Achsparameter 1 Portal 1 \
\ ** Nullpunktkorrektur ** \ -291215
.....
\ Y_Achsdaten \
\ Achsparameter 2 \
.....
\ Achsparameter 1 Portal 1 \
\ ** Nullpunktkorrektur ** \ -616910
3.2 Entering Corrections on the SIPLACE 80 F3
Please observe the following sequence when entering corrections:
−
1
st
turret head
−
2
nd
IC head
Turret head
The PCB camera offset must be altered in REAL.MA. The correction values are entered in the machine
data in
µ
m!
New Kamera_Offset_X = Old Kamera_Offset_X - Arithmetic mean
New Kamera_Offset_Y = Old Kamera_Offset_Y - Arithmetic mean
Example:
Arithmetic mean: x = 26
µ
m
Old camera offset X: 2252
µ
m
New camera offset X: 2252
µ
m - 26
µ
m = 2226
µ
m
Arithmetic mean: y = -46 µm
Old camera offset Y: 78740 µm
New camera offset Y: 78740 µm - (-46µm) = 78786 µm
Entry in REAL.MA:
\ Kameradaten \