00196430-0102-AI_Head_Reconfiguration_Kit_SX_CPP_en_de - 第50页

Brief Description Requirements and Restrictions for the CPP Place ment Head Reconfi guration Duration 50 Assembly Instructions / Montageanleitung Head Reconfiguratio n Kit CPP Requirements and Restrict ions for the CPP P…

100%1 / 78
Brief Description
Options for CPP Tools and Equipment Required
Assembly Instructions / Montageanleitung Head Reconfiguration Kit CPP 49
Tools and Equipment Required
2.2 Tools and Equipment Required
Designation Item No.
Torque wrench 03078400-xx (old version: 00376504-xx)
Extension with joint (170 x SK3) 03042635-xx
Extension straight (170 x SK3) 03043440-xx
Tool extension straight TX20 03073256-xx
Bit holder for TorqueVario screwdriver 03078706-xx
Depth measuring gauge 200 mm 03079617-xx
Pressure test device with measurement cable 00313523-xx
Conversion kit COT insert X 00378465-xx
Mapping Plate SX 560x460 Set
or
Alu Mapping Plate 560 x 460 D, SX1/2
03076118-xx
03076765-xx
Calibration tool version 3 CPP 03010565-xx
Calibration tool version SST23 C&P20 03034148-xx
Assembly Instructions Stationary Camera SX Series 00196608-xx
Assem Assembly Intructions SIPLACE SX 1/2 Noz
-
zle Changer
00196578-xx
Assembly Instructions Reject Bin SIPLACE SX Se
-
ries
00196615-xx
Assembly Instructions Stationary Camera Type 25
SIPLACE X Series, SX1/2, D3 and D1
00194554-xx
Service Manual SX1/2 00196496-xx
Brief Description
Requirements and Restrictions for the CPP Placement Head Reconfiguration Duration
50 Assembly Instructions / Montageanleitung Head Reconfiguration Kit CPP
Requirements and Restrictions for the CPP Placement Head
2.3 Requirements and Restrictions for the CPP Placement Head
The camera type is added during the configuration query of the head reconfiguration kit. The C&P
component camera (type 29) 27x27 digital RK [03018637-xx] is the default.
[03018637-xx] C&P component camera (type 29) 27x27 digital RK (default)
[00119783-xx] CPP head camera (01005) (type 38)
In a placement area with 2 gantries the CPP heads may only be installed on the same height. Thus,
both CPP heads have to be installed in either the high or the low position.
If the CPP head is used together with a TwinHead in a placement area with 2 gantries, the CPP head
may only be installed in the high position.
When using third party feeder modules pay particular attention on the crash danger.
It is not possible to use a vacuum pump together with a CPP head. The head principle requires a
compressed air supply for the time being.
During the placement of a PCB no nozzle change is executed with CPP heads (applies to old modes:
C&P, P&P and Mixed).
In conjunction with a stationary camera the CPP head must always be installed in the high position
and the stationary camera in the low position.
The CPP head can only be used with stationary cameras of function status -04 or higher.
When using a CPP head no magazines of the C&P20A head are allowed on the nozzle changer.
This is monitored by the software.
Reconfiguration Duration
2.3.1 Reconfiguration Duration
The following reconfiguration durations per head can be expected:
Placement head Single-/Double conveyor Task
Disassembling CPP 20 min Without options such as nozzle changers, verify
component reject bin and stationary camera
Disassembling
C&P20A
20 min Without options such as nozzle changer, verify
component reject bin
Disassembling Twin
-
Head
30 min Verify Component reject bin
Assembling CPP 90 / 120 min With mapping and without options such as nozzle
changer, verify component reject bin and stationary
camera
Assembling C&P20A 90 / 120 min With mapping and without options such as nozzle
changer, query component reject bin
Assembling Twin
-
Head
90 / 120 min With mapping and without options such as nozzle
changer, verify component reject bin and stationary
camera
Brief Description
SIPLACE SX 1 Head Modularity SX 70x
Assembly Instructions / Montageanleitung Head Reconfiguration Kit CPP 51
Head Modularity SX 70x
2.4 Head Modularity SX 70x
The CPP head can either be installed in a high or a low position.
The following terms mean:
Installation position low: CPP_L corresponds to a component height of 6 mm maximum.
Installation position high: CPP_H corresponds to a component height of 11.5 mm maximum.
The following head configuration options are available:
SIPLACE SX 1
2.4.1 SIPLACE SX 1
Head configurations on the SIPLACE SX 1
SIPLACE SX 2
2.4.2 SIPLACE SX 2
Head configurations on the SIPLACE SX 2
Gantry 1 Default cameras Options
C&P20A STT 23 ----
CPP_H SST 29 Component camera SST 38
Stat. camera SST 33 (from FS 04 and in low installation posi
-
tion only)
CPP_L SST 29 Component camera SST38
TwinHead SST 33 Stat. camera SST 25 (location 1 only)
3D coplanarity module ST 37 (location 1 only)
Gantry 1 / Gantry 2 Default cameras Options
C&P20A / C&P20A STT 23 ----
CPP_H / CPP_H SST 29 Component camera SST 38
Stat. camera SST 33 possible on location 1 and
2 (from FS 04 and in low installation position on
-
ly)
CPP_L / CPP_L SST 29 Component camera SST38
CPP_H / TwinHead STT 29 (on gan
-
try 1)
Twin SST33 (on
gantry 2)
CPP:
Component camera SST 38
Stat. camera SST 33 (from FS 04 and in low in
-
stallation position only)
TwinHead:
Stat. camera SST 25 (location 1 only)
3D coplanarity module SST 37 (location 1 only)
TwinHead / TwinHead SST 33 Stat. camera SST 25 (location 1 only)
3D coplanarity module ST 37 (location 1 only)