stopper for HF-series for processing area 1 - 第5页

SIPLACE 1 Assembly instructions Special design Stopper for placement area 1 (00166322-01) SIPLACE HF-series 06/2007 Edition 5 1 Assembly instructions S pecial design S topper for placement area 1 (00166322-01) SIPLACE HF…

100%1 / 30
Assembly instructions Special design Stopper for placement area 1 (00166322-01) SIPLACE HF-series
06/2007 Edition
4
SIPLACE 1 Assembly instructions Special design Stopper for placement area 1 (00166322-01) SIPLACE HF-series
06/2007 Edition
5
1 Assembly instructions
Special design Stopper for
placement area 1 (00166322-01)
SIPLACE HF-series
1.1 Functional description
Installing a mechanical stopper module allows the processing area to be varied as required. The
conveyor firmware special design deactivates the light barrier in the placement area and integra-
tes the stopper module with sonar sensor. 1
1.2 Requirements
Software: SR 505.03 SP1, SIPLACE Pro version 5.0, Conveyor firmware TS 610548.hex 1
Hardware: SIPLACE HF, dual conveyor 1
1.3 Restrictions
To calibrate the conveyor edges, the stopper module has to be removed because the minimum
conveyor width with stopper module is 55mm. 1
The maximum board length is reduced. Depending on the stopper setting it varies from 376mm –
347mm. 1
1.4 Scope of delivery
Stopper module
Assembly rail
Socket screws M5 x 10mm
Spacers M5 x 10mm
Cable clips
Cable ties
Conveyor firmware (TS 610548.hex)
Documentation.
1 Assembly instructions Special design Stopper for placement area 1 (00166322-01) SIPLACE HF-series SIPLACE
06/2007 Edition
6
1.5 Required tools
Set of hexagon socket spanners
Set of Philips screwdrivers
Set of fork wrenches
–Side cutter
Hose pliers.