SIPLACE-SX4-DX4-用户手册 - 第194页

Service Work Docking Station for X-Series C omponent Trolley 3.12.5 Replacing the Positions End Switch of the Component Trolley Locking 194 Service Manual SIPLACE SX4/DX4 3.12.5 3 . 1 2 . 5 R e p la c in g t h e P o s it…

100%1 / 298
Service Work
3.12.4 Replacing the Locking Lever [03025104-XX] Docking Station for X-Series Component Trolley
Service Manual SIPLACE SX4/DX4 193
3.12.4
3.12.4 Replacing the Locking Lever [03025104-XX]
Replacing the Locking Lever [03025104-XX]
Parts, equipment and tools
Locking lever [03025104-xx]
Overview
Removal
Installation
Loosely screw in the new locking lever.
Align the locking lever to the edge (3) and tighten the four fastening screws.
Check that the limit switch (4) is actuated when the locking lever is closed. Correct the position of
the locking lever, where necessary.
Check the position end switch function, by trying out the locking procedure.
1. Locking lever – on the left side
2. Locking lever – on the right side
1
2
1. Locking lever
2. Four fastening screws
3. Position end switch
Loosen the four screws (2) (two each at the top and
bottom) fastening the locking lever (1).
Remove the locking lever.
4
3
2
1
Service Work
Docking Station for X-Series Component Trolley 3.12.5 Replacing the Positions End Switch of the Component Trolley Locking
194 Service Manual SIPLACE SX4/DX4
3.12.5
3.12.5 Replacing the Positions End Switch of the Component Trolley Locking Device [03033395-XX]
Replacing the Positions End Switch of the Component Trolley Locking Device
[03033395-XX]
Parts, equipment and tools
Position end switch [03033395-xx]
Overview
Removal
Loosen the two screws fastening the limit switch.
Open the casing of the connector at the back and label the terminal connections.
Disconnect the connection cable for the relevant position end switch, in the connector.
Unthread the connection cable and remove the position end switch.
1. Position end switch – on the left side
2. Position end switch – on the right side
1
2
1. Position end switch with connection cable
2. Two fastening screws
3. Connection cable to connector unit
4. Actuation by locking lever
DANGER!
Switch off the voltage supply
Press the ON/OFF button to switch off and disconnect the
power supply.
NOTICE
Connector for left and right position end switch
The connection cables for the left and right position end switch are connected to a common
connector.
Service Work
3.12.6 Replacing the 40-Fold Feeder Unlock Device [03011582-xx] Docking Station for X-Series Component Trolley
Service Manual SIPLACE SX4/DX4 195
Installation
Loosely screw in the new position end switch.
Run the connection cable to the connector.
Reconnect the connection cable and close the connector casing.
Align the position end switch so that the locking lever actuator switches properly.
Tighten the fastening screws.
Connect the power pack connection cable and press the ON/OFF button to switch on.
Check the position end switch function, by trying out the locking procedure.
3.12.6
3.12.6 Replacing the 40-Fold Feeder Unlock Device [03011582-xx]
Replacing the 40-Fold Feeder Unlock Device [03011582-xx]
Parts, equipment and tools
Feeder unlocking device 40-fold [03011582-XX]
Overview
Removal/installation
The 40-fold feeder unlock device is the same assembly used in the COT insert. The service work is iden-
tical with the procedure used for the COT insert. All necessary service work is described there.
See also
3.10.3 Replacing the 40-Fold Feeder Unlock Device [03011582-xx] [ ➙ 173]
1. 40 fold feeder unlock device
1