SIPLACE-SX4-DX4-用户手册 - 第217页
Service Work 3.14.5 Replacing the Suppressor Module in the Co nnector Unit Bo x [03097216-xx] Vacuum Pump Service Manual SIPLACE SX4/DX4 217 3.14.5 3 . 1 4 . 5 R e p la c in g t h e S u p p r e s s o r M o d u le in t h …

Service Work
Vacuum Pump 3.14.4 Replacing the Power Supply Cable for the Vacuum Pump [03079997-xx]
216 Service Manual SIPLACE SX4/DX4
3.14.4
3.14.4 Replacing the Power Supply Cable for the Vacuum Pump [03079997-xx]
Replacing the Power Supply Cable for the Vacuum Pump [03079997-xx]
Parts, equipment and tools
▪ Cable: power supply for vacuum pump [03079997-xx]
▪ Assembly instructions for vacuum pump SX4, X series S" [00196845-xx]
Overview
Connection on the connector unit box.
Removal/installation
► Also read the "Assembly instructions for the vacuum pump SX4, X series S" [00196845-xx].
See also
1.2 Preparatory Work... [ ➙ 12]
The power supply cable for the vacuum pump leads from
the connector unit box to the vacuum pump.
The connector unit box is located at the bottom of the ma-
chine frame, at location 2.
Terminal Description
X2qr Voltage
X3qr Control
X4qr, X5qr Pumps (sequence not important)
If only one pump is installed, the second connection must be closed with a bridge con-
nector.
X6qr Fan
Cable connections on the vacuum pump:
1. Conductor (1) to connection V1
2. Conductor (2) to connection U1
3. Conductor (3) to connection W1
4. Protective ground at connection (4)
5. Black cable (temperature monitor) on the luster
terminal (5)

Service Work
3.14.5 Replacing the Suppressor Module in the Connector Unit Box [03097216-xx] Vacuum Pump
Service Manual SIPLACE SX4/DX4 217
3.14.5
3.14.5 Replacing the Suppressor Module in the Connector Unit Box [03097216-xx]
Replacing the Suppressor Module in the Connector Unit Box [03097216-xx]
Parts, equipment and tools
▪ EMC suppressor module RC 3x400V 575VAC 4kW [03097216-xx]
Overview
Removal
The suppressor module is located in the connector unit box. The connector unit box is located at the bot-
tom of the machine frame, at location 2.
► For more information about this, read section "3.14.3 Replacing the Connector Unit Box " [ ➙ 215].
Installation
► Observe the following instructions during installation:
See also
1.2 Preparatory Work... [ ➙ 12]
Suppressor module
Connector unit box
1. Installation location of suppressor module
2. The suppressor module is connected to terminal 2, 4
and 6.
NOTICE
Installation instructions
► Cut off the cable lugs and remove approx. 1 cm of insulation from the end of the cable.
► Unlock the terminals (e.g. with a screwdriver) and insert one cable each into terminals 2, 4
and 6.
Service Work
Vacuum Pump 3.14.6 Replacing the Circuit Breaker in the Connector Unit Box [03079445-xx]
218 Service Manual SIPLACE SX4/DX4
3.14.6
3.14.6 Replacing the Circuit Breaker in the Connector Unit Box [03079445-xx]
Replacing the Circuit Breaker in the Connector Unit Box [03079445-xx]
Parts, equipment and tools
▪ Circuit breaker 5SY6 3pol 6A C [03079445-xx]
Removal/Installation
The circuit breaker is located in the connector unit box. The connector unit box is located at the bottom
of the machine frame, at location 2.
► For more information about this, read section "3.14.3 Replacing the Connector Unit Box " [ ➙ 215].
See also
1.2 Preparatory Work... [ ➙ 12]
3.14.7
3.14.7 Replacing the Button in the Connector Unit Box [03072025-xx]
Replacing the Button in the Connector Unit Box [03072025-xx]
Parts, equipment and tools
▪ Button 5TE4 800 [03072025-xx]
Removal/Installation
The button is located in the connector unit box. The connector unit box is located at the bottom of the
machine frame, at location 2.
► For more information about this, read section "3.14.3 Replacing the Connector Unit Box " [ ➙ 215].
See also
1.2 Preparatory Work... [ ➙ 12]
3.14.8
3.14.8 Replacing the Relay Terminal Block in the Connector Unit Box [03086538-xx]
Replacing the Relay Terminal Block in the Connector Unit Box [03086538-xx]
Parts, equipment and tools
▪ Relay terminal block DEK-REL-G24/21 24VDC 1 Wech [03086538-xx]
Removal/Installation
The relay terminal block is located in the connector unit box. The connector unit box is located at the
bottom of the machine frame, at location 2.
► For more information about this, read section "3.14.3 Replacing the Connector Unit Box " [ ➙ 215].
See also
1.2 Preparatory Work... [ ➙ 12]
3.14.9
3.14.9 Replacing the Diode Terminal Block in the Connector Unit Box [03006763-xx]
Replacing the Diode Terminal Block in the Connector Unit Box [03006763-xx]
Parts, equipment and tools
▪ Diode terminal block 2.5 qmm gy 4L. with 1N4007 [03006763-xx]
Removal/Installation
The diode terminal block is located in the connector unit box. The connector unit box is located at the
bottom of the machine frame, at location 2.
► For more information about this, read section "3.14.3 Replacing the Connector Unit Box " [ ➙ 215].
See also
1.2 Preparatory Work... [ ➙ 12]