SIPLACE-SX4-DX4-用户手册 - 第241页

Settings 5.4.6 Track Signals and Zero Pulse Gantry Settings Service Manual SIPLACE SX4/DX4 241 Measuring the Digita l Zero Pulse Signal Measurement procedure for checki ng the digital zero pulse signa l and the digita l …

100%1 / 298
Settings
Gantry Settings 5.4.6 Track Signals and Zero Pulse
240 Service Manual SIPLACE SX4/DX4
Manually move the gantry over the first zero pulse.
The following picture should appear on the oscilloscope.
Correctly adjusted read unit
1. There should be no interference pulse in the toler-
ance space of - 0.3 V.
2. The analog zero pulse has to exceed the switching
threshold by more then 0.3V
3. Initial position
4. Analog zero pulse
5. Digital zero pulse
Incorrectly adjusted read unit or contaminated zero pulse
1. Analog track signal A and B
2. Analog zero pulse
3. Digital zero pulse
Settings
5.4.6 Track Signals and Zero Pulse Gantry Settings
Service Manual SIPLACE SX4/DX4 241
Measuring the Digital Zero Pulse Signal
Measurement procedure for checking the digital zero pulse signal and the digital track signals.
NOTICE
Checking the zero pulse
You can also use the BNC socket on the axis test box to check the zero pulse signal (inverted
display of zero pulse signal). The digital signals (for error monitoring purposes) can be checked
at connectors X10 and X24 of the gantry and head interface. (Calculate extra time for Y axes,
dismounting the covers).
NOTICE
Measurement procedure
The procedure for measuring the digital zero pulse is identical to that for measuring the analog
zero pulse.
Settings
Gantry Settings 5.4.6 Track Signals and Zero Pulse
242 Service Manual SIPLACE SX4/DX4
X10 on the gantry Interface for the Y Axis
X24 on the Head Interface for the X Axis
5.4.6.2
5.4.6.2 Checking the Track Signals
Checking the Track Signals
Analog Track Signals
To check the track signals, connect the track signal tester and the oscilloscope. (see "5.4.6.1.1 Measur-
ing the Analog Zero Pulse Signal" [ 239])
Switch the machine "ON"
Switch the track signal tester to Calibrate the oscilloscope
Set the oscilloscope to DC, Refr., Non Store, Auto (20 ms)
Voltages V/Division decrease up to 0.5 V/Div.
Set the oscilloscope to X/Y --> an illuminated point will appear!
Move the point into the middle of the display.
Set the measuring system tester to Sinus amplifier output
Manually move the selected axis back and forth.
Connector assignment X10:
1. Pin 1 Ground
2. Pin 2 Track A
3. Pin 3 Track A\
(A\ means inverted A)
4. Pin 4 Ground
5. Pin 5 Track B
6. Pin 6 Track B\
7. Pin 7 +5V
8. Pin 8 Track N
9. Pin 9 Track N\
10. Pin 10 Key
Connector assignment X24:
1. Pin 1 Ground
2. Pin 2 Track A
3. Pin 3 Track A\
4. Pin 4 Ground
5. Pin 5 Track B
6. Pin 6 Track B\
7. Pin 7 +5V
8. Pin 8 Track N
9. Pin 9 Track N\
10. Pin 10 Key