SIPLACE-SX4-DX4-用户手册 - 第257页
Settings 5.5.2 Teaching the Sonar Sensor PXS240 Conveyor Settings Service Manual SIPLACE SX4/DX4 257 ► To tea ch, press t he button o n the pro gramming c able for ap prox. 3 sec onds, until the LED on the sensor begins …

Settings
Conveyor Settings 5.5.2 Teaching the Sonar Sensor PXS240
256 Service Manual SIPLACE SX4/DX4
5.5.2
5.5.2 Teaching the Sonar Sensor PXS240
Teaching the Sonar Sensor PXS240
Parts, equipment and tools
▪ Setting gauge for ultrasonic sensors [03076989-xx]
▪ Programming cable for PXS240 sensor [03073330-xx]
Setting
► Use the software to move the conveyor sides into the position which allows you best access. As an
alternative, you can loosen the clamps for the relevant sides in dual conveyors.
► Secure the machine by attaching relevant warning tags. Do not switch the machine off as the setting
would then not be applied. Observe the instructions in section "1.2 Preparatory Work..." [ ➙ 12],
NOTICE
2 versions of the programming cable
In the meantime, a second version of the programming cable (UB-PROG2) has been supplied.
The function of this programming cable is similar to that of programming cable PXS240. Fur-
thermore, two adapter cables (M8/M12 adapter and M12/M8 adapter) can be connected for the
sensor and the conveyor control cable.
The previous programming cable will now be available under the name "UB-PROG4-V31" (old
name was PXS240) and the item no.: [03073330-xx].
► See also"4.10 Programming Cable for PXS240 Sensor [03073330-xx]" [ ➙ 223]
► To use the new programming cable, proceed as follows:
Switch on the machine and place the gauge onto the conveyor, as described. To teach,
press the "A1" button on the programming cable for approx. 3 seconds, until the LED on the
sensor begins to flash. The "A2" button on the UB-PROG2 is not needed.
Connecting the programming cable (example of X4I
shown)
1. Programming cable for PXS240 ultrasonic sensor
2. Press-fit connection for the ultrasonic sensor
3. Ultrasonic sensor PXS240
► Unplug the press-fit connection from the ultrasonic
sensor and connect the programming cable between
this and the ultrasonic sensor.

Settings
5.5.2 Teaching the Sonar Sensor PXS240 Conveyor Settings
Service Manual SIPLACE SX4/DX4 257
► To teach, press the button on the programming cable for approx. 3 seconds, until the LED on the
sensorbegins to flash.
The switching threshold is set accordingly.
► Remove the setting gauge.
► Loosen the programming cable connections and reconnect the ultrasonic sensor directly to the con-
nection at the machine end.
See also
3.6.1 Loosening the Conveyor Side Clamps [ ➙ 95]
Fitted ultrasonic sensor with programming cable and ad
-
justment gauge (example of X4I shown)
1. Setting gauge
2. Programming cable (fitted)
3. LED on ultrasonic sensor
► The distance to the PCB is defined with the setting
gauge.
Position the setting gauge over the conveyor, so that
it is above the reception area of the ultrasonic sensor.
CAUTION!
Make sure that the gauge is used the right way round.
The gauges can be used for different conveyor types.
Make sure that the gauges are always used the right way
round.
▪ 3mm gap for the X conveyor
▪ 2mm gap for the SX conveyor

Settings
Conveyor Settings 5.5.3 Conveyor Sides
258 Service Manual SIPLACE SX4/DX4
5.5.3
5.5.3 Conveyor Sides
Conveyor Sides
5.5.3.1
5.5.3.1 Setting the Parallelism of the Single Conveyor Sides
Setting the Parallelism of the Single Conveyor Sides
Overview
Setting
► Use the software to move the conveyor side into the position which allows you best access.
► Switch off the machine, disconnect it from the power supply and secure it to prevent unauthorized
reactivation. Observe the instructions in section "1.2 Preparatory Work..." [ ➙ 12].
► Loosen the screws fastening the width adjustment drive. The toothed belt of the width adjustment
should then have enough play so that you can move the width adjustment units independently of one
another. You may need to loosen the toothed belt from the deflection pulleys.
► Push the conveyor side manually to its outermost position, so that the adjustment units are posi-
tioned against the spindle stops.
► If you have loosened the toothed belt from the deflection pulleys, insert this again now.
► Tighten the screws fastening the drive again and set the belt tension to 27 +/-2 Hz. (see "5.5.1.2 Set-
ting the Width Adjustment Belt Tension" [ ➙ 252]).
Verification
► The flexible conveyor side must have the same distance to the mounting frame at all points.
► Pull the toothed belt to move the flexible conveyor side manually as far as the edge. The adjustment
units must touch the stops at the same time.
► Calibrate the width adjustment motor.
1. Flexible conveyor side wall (shown on the left here)
2. Adjustment units (3x)
3. Toothed belt of width adjustment
4. Width adjustment drive
5. Fixed conveyor side (shown on the right here)