SIPLACE-SX4-DX4-用户手册 - 第283页
Description of the circuit boards 6.2.4 X base adapter C&P [03045647-xx] Ga ntry Service Manual SIPLACE SX4/DX4 283 Before version 05 Base adap ter bo ard (without HCU) LEDs - meanings The voltage monitors trigger as…

Description of the circuit boards
Gantry 6.2.4 X base adapter C&P [03045647-xx]
282 Service Manual SIPLACE SX4/DX4
6.2.4
6.2.4 X base adapter C&P [03045647-xx]
X base adapter C&P [03045647-xx]
This board is used for C&P20x and CPP heads on X series S and SX4/DX4 machines.
Version 05
03045647-05
LED [03045647-05]
Switch S1 [03045647-05]
Switch S1 sets the link voltage for the Z axis
If the setting is incorrect, no damage will be done but an HCU error message will be issued.
NOTICE
C&P20 P
The X basis adapter needs at least function state 08 for the C&P20 P head.
LED Color Status Signal name Description
H1 GN ON CO_SENSOR CO sensor active
H2 GN ON - The programming plug for the HCU is con-
nected
H3 RD ON FPGA_TEST_6 1.5V power supply error
H4 RD ON FPGA_TEST_2 3.3V power supply error
H5 RD ON FPGA_TEST_4 5V power supply error
H6 RD ON FPGA_TEST_1 15V power supply error
H7 RD ON FPGA_TEST_3 DP power supply error, temp. without func-
tion
H8 RD ON FPGA_TEST_5 24V power supply error
H9 RD ON POWERFAIL_LOCAL PowerFail on circuit board
Switch Status Function
S1 40V Intermediate link voltage for Z axis -->
C&P20
150V Intermediate link voltage for Z axis --> CPP

Description of the circuit boards
6.2.4 X base adapter C&P [03045647-xx] Gantry
Service Manual SIPLACE SX4/DX4 283
Before version 05
Base adapter board (without HCU)
LEDs - meanings
The voltage monitors trigger as soon as the nominal voltage is undershot by 5%.
1 Switch S1 (see above) 2 X4 – for checking the voltages
3 Connection to the head interface C700 4 X1 and X2 – to the head
5 X4, X14 and X15 – for the HCU 6 DIP switch S2
7 7 segment display. 8 LEDs H1-H11
LED Description
H1 BE-S Lights up green, when the CO sensor is actuated
H2 RS232 Lights up, when the programming connector for the HCU is connected (not
designed for Service)
H3 1V5 1.5 voltage monitor - lights up red in case of an error
H4 3V3 3.3 voltage monitoring - lights up red in case of an error
H5 5V 5 voltage monitor - lights up red in case of an error
H6 15V 15 voltage monitoring - lights up red in case of an error
H7 DP DP voltage monitoring (currently without function)
H8 24V 24 V voltage monitoring - lights up red in case of an error
H9 LOC Voltage monitor local - lights up red as soon as one of the voltage monitors
triggers.
H10 Ok HCU-OK - HCU running without errors
H11 ERR HCU error - HCU reports an error

Description of the circuit boards
Gantry 6.2.4 X base adapter C&P [03045647-xx]
284 Service Manual SIPLACE SX4/DX4
Switch S2
All switches must be set to OFF. If needed, the HCU can be reset with S3.
Further Information
Base adapter for CPx [03045647-xx] on machines with HCU
Switch Description
S1 S0 Gantry encoding (currently not used)
S2 S1 Gantry encoding (currently not used)
S3 Reset Reset HCU
S4 Boot HCU bootstrap function activated (not designed for Service)
1 X3 Connection to the head interface board
C700
5 Test connector for FPGA
2 X4, X14, X15 – connector for HCU 6 X1-X2 flat ribbon connection for CPP or
C&P20
3 Switch S1 intermediate circuit voltage
Z axis
40V C&P20 (switch top)
150V CPP(switch bottom)
7 X6 Programming connector for FPGA
4 LED H3- H9 8 X7 Test connector HCU