SIPLACE-SX4-DX4-用户手册 - 第43页

Service Work 3.2.7 Replacing the Load Add Circuit (A4) [03094585Sxx] Electric al System Service Manual SIPLACE SX4/DX4 43 3.2.7 3 . 2 . 7 R e p la c in g t h e L o a d A d d C ir c u it ( A 4 ) [ 0 3 0 9 4 5 8 5 S x x ] …

100%1 / 298
Service Work
Electrical System 3.2.6 Replacing the Rectifiers (U1 to U3, U20 to U24)
42 Service Manual SIPLACE SX4/DX4
3.2.6
3.2.6 Replacing the Rectifiers (U1 to U3, U20 to U24)
Replacing the Rectifiers (U1 to U3, U20 to U24)
Parts, equipment and tools
U1, U3: rectifier S101-B6U 160-08 [00341246-xx]
U2: rectifier S61-B2U 28-10 [03080931-xx]
U20 to U24: rectifier S61-B2U 28-04 [03079959-xx]
Silicon-free heat-conductive paste (not electrically conductive)
Thermal conductivity 1.0 W/mK
Dielectric strength 40kV/mm
Temperature range -40°C to +200°C
Flash point >280°C
Suggested supplier: Bürklin OHG, order number 80 B 531
Overview
Removal
Switch off the machine, disconnect it from the power supply and secure it to prevent unauthorized
reactivation. Observe the instructions in section "1.2 Preparatory Work..." [ ➙ 12].
Loosen the screws fastening the cover and swing the cover towards the front. The pulsed power
packs are fitted to the cover. These are swung open together with the cover.
Unplug all connections to the rectifiers. You may want to mark their positions, to make clear assign-
ment easier later on.
Loosen the screws fastening the rectifier and remove the rectifier.
Installation
Follow the removal instructions in reverse order for installation. Also observe the following instruc-
tions:
1. Cover
2. Rectifier U24
3. Rectifier U3
4. Rectifier U1
5. Rectifier U2
6. Rectifier U20 to U23
CAUTION
Installation instructions
Apply a heat-conductive paste between the metal frame and the rectifier.
Service Work
3.2.7 Replacing the Load Add Circuit (A4) [03094585Sxx] Electrical System
Service Manual SIPLACE SX4/DX4 43
3.2.7
3.2.7 Replacing the Load Add Circuit (A4) [03094585Sxx]
Replacing the Load Add Circuit (A4) [03094585Sxx]
Parts, equipment and tools
FBG dyn. load add circuit intermediate cycle [03094585Sxx]
Overview
Removal
Switch off the machine, disconnect it from the power supply and secure it to prevent unauthorized
reactivation. Observe the instructions in section "1.2 Preparatory Work..." [ ➙ 12].
Loosen the screws fastening the cover and swing the cover towards the front. The pulsed power
packs are fitted to the cover. These are swung open together with the cover.
Unplug all connections to the load add circuit. You may want to mark their positions, to make clear
assignment easier later on.
Loosen the screws fastening the load add circuit and remove it.
Installation
Follow the removal instructions in reverse order for installation.
1. Cover
2. Line filter (Z1)
3. Load add circuit (A4)
Service Work
Electrical System 3.2.8 Replacing the Line Filter (Z1) [03078386-xx]
44 Service Manual SIPLACE SX4/DX4
3.2.8
3.2.8 Replacing the Line Filter (Z1) [03078386-xx]
Replacing the Line Filter (Z1) [03078386-xx]
Parts, equipment and tools
Line filter for 3-phase systems 36 A (Z1) [03078386-xx]
Overview
Removal
Switch off the machine, disconnect it from the power supply and secure it to prevent unauthorized
reactivation. Observe the instructions in section "1.2 Preparatory Work..." [ ➙ 12].
Loosen the screws fastening the cover and swing the cover towards the front. The pulsed power
packs are fitted to the cover. These are swung open together with the cover.
Unplug all connections to the line filter. You may want to mark their positions, to make clear assign-
ment easier later on.
Loosen the screws fastening the line filter and remove the line filter.
Installation
Follow the removal instructions in reverse order for installation.
1. Cover
2. Line filter (Z1)
3. Load add circuit (A4)