SIPLACE-SX4-DX4-用户手册 - 第89页
Service Work 3.5.10 Replacing the Gantry Interface Gantries Service Manual SIPLACE SX4/DX4 89 3.5.10 3 . 5 . 1 0 R e p la c in g t h e G a n t r y I n t e r f a c e Replacing the Gantry Interface Parts, Equipment and Too…

Service Work
Gantries 3.5.9 Replacing the Trailing Cable Interface
88 Service Manual SIPLACE SX4/DX4
3.5.9
3.5.9 Replacing the Trailing Cable Interface
Replacing the Trailing Cable Interface
Parts, Equipment and Tools
▪ Trailing cable interface gantry 2 and 4 assembly [03071356-xx] or
▪ Trailing cable interface gantry 1 and 3 assembly [03071355-xx]
Overview
Removal
► Switch off the machine, disconnect it from the power supply and secure it to prevent unauthorized
reactivation. Observe the instructions in section "1.2 Preparatory Work..." [ ➙ 12].
► Loosen the screws fastening the cover on the trailing cable interface and remove the cover.
► Unplug the electrical connections to the trailing cable interface. You may want to mark their positions,
to make clear assignment easier later on.
► Loosen the two screws fastening the trailing cable interface and remove the interface from the ma-
chine.
Installation
► Follow the removal instructions in reverse order for installation.
1. Cover on the trailing cable interface
2. Vision hotlink adapter
3. Trailing interface

Service Work
3.5.10 Replacing the Gantry Interface Gantries
Service Manual SIPLACE SX4/DX4 89
3.5.10
3.5.10 Replacing the Gantry Interface
Replacing the Gantry Interface
Parts, Equipment and Tools
▪ Gantry interface gantry 1 and 3 [03059908-xx]
▪ Gantry interface gantry 2 and 4 [03059909-xx]
Overview
Removal
► Switch off the machine, disconnect it from the power supply and secure it to prevent unauthorized
reactivation. Observe the instructions in section "1.2 Preparatory Work..." [ ➙ 12].
► Unplug the electrical connections to the gantry interface. You may want to mark their positions, to
make clear assignment easier later on.
► Loosen the two screws fastening the gantry interface and remove the interface from the machine.
Installation
► Follow the removal instructions in reverse order for installation.
1. Gantry interface
2. Trailing cable holder on gantry

Service Work
Gantries 3.5.11 Replacing the GCU [03052200-xx]
90 Service Manual SIPLACE SX4/DX4
3.5.11
3.5.11 Replacing the GCU [03052200-xx]
Replacing the GCU [03052200-xx]
Parts, equipment and tools
▪ Positioning control for the gantry axes GCU [03052200-xx]
Overview
Removal
► Switch off the machine, disconnect it from the power supply and secure it to prevent unauthorized
reactivation. Observe the instructions in section "1.2 Preparatory Work..." [ ➙ 12].
► Unplug all connections on the GCU. You may want to mark their positions, to make clear assignment
easier later on.
► Loosen the screws fastening the mount and then remove the mount.
► Remove the GCU from the machine.
Installation
► Follow the removal instructions in reverse order for installation. Also observe the following instruc-
tions:
1) to 4) GCUs
The GCUs are located in a rack unit between locations 1
and 2.
The assignment of GCUs to gantries differs according to
the machine type. Observe the instructions in section
"5.4.7 Overview of GCUs" [ ➙ 247].
CAUTION
Installation instructions
► Use the DIP switch to set the gantry ID on the GCU. (see "5.4.7 Overview of GCUs"
[ ➙ 247]).
► Check the firmware and perform a download, if needed. (see "5.8.1 Firmware Download
(SW 70x)" [ ➙ 266]).