CX200-4(Maint) - 第184页

Error ID Item Description 1 10301 L CONVEYOR WIDTH DA T A THE DRIVER DA T A WAS DETECTED OUTSIDE OF THE POSSIBLE RANGE. (Cause 1) The “Product Change” tab sheet was opened and the manual axis operation was performed to w…

100%1 / 299
Error ID Item Description
100501 X/Y Chute Wd. Chute Up-Down The chute wd. Has not descended smoothly resulting in
an overtime alarm.
100502 X/Y Chute Wd. Chute Up-Down The chute wd. Has not ascended smoothly resulting in
an overtime alarm.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
100601 X/Y Chute Wd. Communication The controller can not run.
100602 X/Y Chute Wd. Communication Controller interior is out of order.
100603 X/Y Chute Wd. Communication Controller in communication error condition.
100604 X/Y Chute Wd. Communication Controller incomplete resulting in an overtime alarm.
(Cause 1) Self-Diagnostics Error Message.
(Cause 2) The voltage of the stabilization power supply unit (PSU) is abnormal.
(Remedy 1) Zero all axes and re-start the operation.
(Remedy 2) Check the stabilization power supply unit.
110101 L CONVEYOR WIDTH ORIGIN OUTPUT SIGNAL FROM THE PULSE MOTOR DRIVER WAS
NOT DETECTED.
110102 L CONVEYOR WIDTH ORIGIN FEEDBACK VALUE IS INDEFINITE.
110103 L CONVEYOR WIDTH ORIGIN L COVEYOR WIDTH IS NOT AT ORIGIN.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
110201 L CONVEYOR WIDTH TIMING TASK HAS NOT BEEN COMPLETED UNABLE TO
CONTINUE.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
01 10-003 2-94 AFO01ETRP
3.3 Error IDs and Remedial Procedures
Error ID Item Description
110301 L CONVEYOR WIDTH DATA THE DRIVER DATA WAS DETECTED OUTSIDE OF
THE POSSIBLE RANGE.
(Cause 1) The “Product Change” tab sheet was opened and the manual axis operation was
performed to widen the width from the origin position. Or, the manual axis operation
was performed to make the width narrower.
(Remedy 1) Cancel the error display with the [RETURN] button and perform the manual axis
operation in the correct direction.
110401 L CONVEYOR WIDTH LIMIT LIMIT (+) ERROR HAS BEEN DETECTED. ; BPH77 E/NR
110402 L CONVEYOR WIDTH LIMIT LIMIT (−) ERROR HAS BEEN DETECTED. ; BPH78 E/NR
(Cause 1) An optical beam of the sensor is shielded.
(Cause 2) Dirt adheres to the sensor and the optical beam is shielded.
(Cause 3) The sensor is defective.
(Remedy 1) Turn off the power supply and move the conveyor width with the manual knob for
easier operation. Re-attach the light shield plate or the sensor securely (remove
the looseness).
Re-supply power to the machine and zero the L conveyor width.
Open the “Product Change” tab sheet and confirm that the L conveyor width can
be changed as specified.
If necessary, correct the “Clearance” data for the conveyor width.
(Remedy 2) Wipe off dirt on the sensor and zero the L conveyor again.
(Remedy 3) It is required to replace the sensor.
Contact our service personnel for details.
120101 R CONVEYOR WIDTH ORIGIN OUTPUT SIGNAL FROM THE PULSE MOTOR DRIVER WAS
NOT DETECTED.
120102 R CONVEYOR WIDTH ORIGIN FEEDBACK VALUE IS INDEFINITE.
120103 R CONVEYOR WIDTH ORIGIN R CONVEYOR WIDTH IS NOT AT ORIGIN.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
120201 R CONVEYOR WIDTH TIMING TASK HAS NOT BEEN COMPLETED UNABLE TO
CONTINUE.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
01 10-003 2-95 AFO01ETRP
3.3 Error IDs and Remedial Procedures
Error ID Item Description
120301 R CONVEYOR WIDTH DATA THE DRIVER DATA WAS DETECTED OUTSIDE OF THE
POSSIBLE RANGE.
(Cause 1) The “Product Change” tab sheet was opened and the manual axis operation was
performed to widen the width from the origin position. Or, the manual axis operation
was performed to make the width narrower.
(Remedy 1) Cancel the error display with the [RETURN] button and perform the manual axis
operation in the correct direction.
120401 R CONVEYOR WIDTH LIMIT LIMIT ERROR HAS BEEN DETECTED. ; BPH79 E/NR
120402 R CONVEYOR WIDTH LIMIT LIMIT ERROR HAS BEEN DETECTED. ; BPH80 E/NR
(Cause 1) An optical beam of the sensor is shielded.
(Cause 2) Dirt adheres to the sensor and the optical beam is shielded.
(Remedy 1) Turn off the power supply and move the conveyor width with the manual knob for
easier operation. Re-attach the light shield plate or the sensor securely (remove
the looseness).
Re-supply power to the machine and zero the L conveyor width.
Open the “Product Change” tab sheet and confirm that the L conveyor width can
be changed as specified.
If necessary, correct the “Clearance” data for the conveyor width.
(Remedy 2) Wipe off dirt on the sensor and zero the L conveyor again.
130101 P.C.B. SUPPORT PINS OUTPUT SIGNAL FROM THE PULSE MOTOR DRIVER
UP/DOWN ORIGIN WAS NOT DETECTED.
130102 P.C.B. SUPPORT PINS FEEDBACK VALUE IS INDEFINITE.
UP/DOWN ORIGIN
130103 P.C.B. SUPPORT PINS THE P.C.B. SUPPORT PINS UP/DOWN WIDTH IS NOT AT
UP/DOWN ORIGIN ORIGIN.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
130201 P.C.B. SUPPORT PINS TASK HAS NOT BEEN COMPLETED UNABLE TO CON
UP/DOWN TIMING TINUE.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
01 10-003 2-96 AFO01ETRP
3.3 Error IDs and Remedial Procedures