CX200-4(Maint) - 第201页
Error ID ltem Description 440101 Cam Phase Gap of cam phase has been detected. (Cause 1) Self-Diagnostics Error Message (Remedy 1) Zero all axes and re-start the operation. When the machine cannot be set to its normal co…

3.3 Error IDs and Remedial Procedures
01 10-003 2-111 AFO01ETRP
Error ID Item Description
430701 Linear Measure Linear measure alarm signal was detected.
430702 Linear Measure Communication error in linear measure system.
430703 Linear Measure Upper limit of linear measure data was out of range.
430704 Linear Measure Lower limit of linear measure data was out of range.
430705 Linear Measure Linear measure dirty signal was detected.
430706 Linear Measure Linear measure SYNC signal has been lost.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
430801 Cam-Positioner Cam-positioner alarm signal was detected.
(Cause 1) The cam positioner is abnormal.
(Remedy 1) Press the [RETURN] button to cancel the error display and contact our service
personnel for the remedy.
430901 Auto Recovery Cannot recover sequence.
430a01 Oil Cooler Oil cooler alarm signal was detected.
430a02 Oil Cooler
430b01 Cooling FAN Cooling FAN alarm signal was detected.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.

Error ID ltem Description
440101 Cam Phase Gap of cam phase has been detected.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
440201 The Comp. Placement Lever The structure of comp. placement lever was not activated.
440202 The Comp. Placement Lever The comp. placement lever moves despite being held by stop-
per.
440203 The Comp. Placement Lever The comp. placement lever does not move even though stop-
per was open.
(Cause 1) The sensor is defective or is not adjusted to the correct position.
The sensor does not turn ON or OFF due to adhered dirt.
(Remedy 1) Wipe off dirt on the sensor and zero all axes again.
440301 The Comp. Pick-Up Lever The structure of comp. pick-up lever was not activated.
440302 The Comp. Pick-Up Lever The comp. pick-up lever moves despite being held by stopper.
440303 The Comp. Pick-Up Lever The comp. pick-up lever does not move even though stopper
was open.
(Cause 1) The sensor is defective or is not adjusted to the correct position.
The sensor does not turn ON or OFF due to adhered dirt.
(Remedy 1) Wipe off dirt on the sensor and zero all axes again.
01 10-003 2-112 AFO01ETRP
3.3 Error IDs and Remedial Procedures

Error ID ltem Description
440401 The Feeder Index Lever #2 The structure of feeder index lever was not activated.
(Cause 1) An optical beam of the sensor is always kept in the “E/NR” or the “E/R” condition.
(ENR: Light Emitted and Not Received, E/R: Light Emitted and Received)
(Remedy 1) Press the [RETURN] button to cancel the error display and check if the optical
beam of the sensor is set in the “E/NR” or the “E/R” condition.
• Cover the optical beam of the sensor with a piece of paper to see if the optical
beam can be shielded or received and check the reaction.
• If necessary, wipe off dirt on the sensor and then perform the zeroing operation
on all axes.
Note: Never detach the sensor. Otherwise, the optical axis will shift, causing
the timing to drift.
Whenever the sensor was detached, consult our service personnel for
the attachment.
440402 The Feeder Index Lever #2 The feeder index lever moves despite being held by stopper.
(Cause 1) The optical beam of the sensor was shielded.In normal cases, the sensor must be in
the “E/R” mode. (E/R: Light Emitted and Received)
(Remedy 1) Press the [RETURN] button to cancel the error display and check that the optical
beam of the sensor is in the “E/NR” mode. (E/NR: Light Emitted and Not Re-
ceived)
• Cover the optical beam of the sensor with a piece of paper to see if the optical
beam can be shielded or received and check the reaction.
• If necessary, wipe off dirt on the sensor and then perform the zeroing operation
on all axes.
Note: Never detach the sensor. Otherwise, the optical axis will shift, causing
the timing to drift.
Whenever the sensor was detached, consult our service personnel for
the attachment.
440403 The Feeder Index Lever #2 The feeder index lever does not move even though stopper
was open.
(Cause 1) The optical beam of the sensor was received. In normal cases, the sensor must be in
the “E/NR” mode. (E/NR: Light Emitted and Not Received)
(Remedy 1) Press the [RETURN] button to cancel the error display and check that the optical
beam of the sensor is in the “E/NR” mode. (E/NR: Light Emitted and Not Re-
ceived)
• Cover the optical beam of the sensor with a piece of paper to see if the optical
beam can be shielded or received and check the reaction.
• If necessary, wipe off dirt on the sensor and then perform the zeroing operation
on all axes.
Note: Never detach the sensor. Otherwise, the optical axis will shift, causing
the timing to drift.
Whenever the sensor was detached, consult our service personnel for
the attachment.
01 10-003 2-113 AFO01ETRP
3.3 Error IDs and Remedial Procedures