CX200-4(Maint) - 第205页

Error ID ltem Description 440801 Cutter THE CUTTER FORW ARD CONFIRMA TION WAS NOT ACTI- V A TED. ; BPH32 440802 Cutter THE CUTTER RETURN CONFIRMA TION W AS NOT ACTI- V A TED. ; BPH33 (Cause 1) An o p tical beam of the se…

100%1 / 299
Error ID ltem Description
440601 Nozzle Change The nozzle change lever was not activated.
440602 Nozzle Change The nozzle change lever moves despite being held by stop
per.
440603 Nozzle Change The nozzle change lever does not move even though stopper
was open.
Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
440701 Nozzle Change/Return The nozzle change/return lever was not activated.
440702 Nozzle Change/Return The nozzle change/return lever moves despite being held by
stopper.
440703 Nozzle Change/Return The nozzle change/return lever does not move even though
stopper was open.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
01 10-003 2-115 AFO01ETRP
3.3 Error IDs and Remedial Procedures
Error ID ltem Description
440801 Cutter THE CUTTER FORWARD CONFIRMATION WAS NOT ACTI-
VATED. ; BPH32
440802 Cutter THE CUTTER RETURN CONFIRMATION WAS NOT ACTI-
VATED. ; BPH33
(Cause 1) An optical beam of the sensor was not shielded at all.
This error occurs when the cutter blades do not close completely.
Example: The cutter blades were damaged because they were activated to cut com-
ponents.
(Remedy 1) Press the [RETURN] button to cancel the error display and check the cutter
blades.
If necessary, replace the cutter blades with new ones.
Check the ON/OFF operation of the cutter forward movement check photosensor
(BPH32) and the cutter backward movement check photosensor (BPH33) in
the cutter section through the manual subsystem operation in the “MNL OPN.”
window.
450101 PEC INSPECT
450102 PEC INSPECT Time-Out Error
450103 PEC INSPECT GUI starting failure.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
01 10-003 2-116 AFO01ETRP
3.3 Error IDs and Remedial Procedures
Error ID ltem Description
460101 PEC Inspect P.E.C. Mark #1 (Global)
460201 PEC Inspect P.E.C. Mark #2 (Global)
460301 PEC Inspect P.E.C. Mark #3 (Global)
460401 PEC Inspect P.E.C. Mark #1 (Image)
460501 PEC Inspect P.E.C. Mark #2 (Image)
460601 PEC Inspect P.E.C. Mark #3 (Image)
460701 PEC Inspect P.E.C. Mark #1 (Local)
460801 PEC Inspect P.E.C. Mark #2 (Local)
460901 PEC Inspect P.E.C. Mark #3 (Local)
460a01 PEC Inspect P.E.C. Recognition Test
460b01 PEC Inspect P.E.C. Recog. Light Teach
460c01 PEC Inspect Error Response of P.E.C. Recog. Command
Refer to “4.3.3 P.E.C. Recognition Errors” for “(Cause 1)” and “(Remedy 1)”.
01 10-003 2-117 AFO01ETRP
3.3 Error IDs and Remedial Procedures