CX200-4(Maint) - 第253页
Recognition Error ID Item Description 01 31 3 00001 Error in “Camera POSITION X or POSITION Y” ---- Data. 01 31 3 00003 Error in “Camera ANGLE” Data. ---- 01 31 3 00007 Error in “Camera 1 – 2 X or Y” Data. ---- 01 32 3 0…

4.3 Recognition Error IDs and Remedial Procedures
4.3.1 Recognition Communication and Data Errors
AA BB C DDDDD
Detail Code
Secondary Error Classification
1: Recognition Communication
Data Range Error
2: Input Data Assembly Error
3: Input Data Error
Primary Error Classification
10 to 70: Communication Commands
90: Communication Procedure
91: Command Error
92: Response Error
Classification (01) of Recognition Functions
When an error ID other than the described ones is issued, con-
tact our service personnel for some advice.
Table 4B9
Recognition Error ID Item Description
01 ** 1 ***** Error in Recognition Communication Data -----
(Cause) An error was found in the recognition
communication data.
(Remedy 1) Contact our service personnel for details.
01 21 3 00000 “P.E.C. Lighting #2“ is not Connected! -----
(Cause) Failed in confirmation to the connection of the lighting unit for ceramic boards.
(Remedy 1) Contact our service personnel for some advice.
01 30 3 00001 Error in “Camera MAGNIFICATION X or -----
MAGNIFICATION Y“ Data.
(Cause) Wrong parameters are set.
(Remedy 1) Set the correct data.
4.3 Recognition Error IDs and Remedial Procedures
01 10-003 2-163 AFO01ETRP
Note

Recognition Error ID Item Description
01 31 3 00001 Error in “Camera POSITION X or POSITION Y” ----
Data.
01 31 3 00003 Error in “Camera ANGLE” Data. ----
01 31 3 00007 Error in “Camera 1 – 2 X or Y” Data. ----
01 32 3 00002 Error in “Camera GAIN or LEVEL” Data. ----
01 33 3 00001 Error in “Nozzle Offset High Mag. X or Y” Data. ----
01 33 3 00002 Error in “Nozzle Offset Low Mag. X or Y” Data. ----
01 33 3 00004 Error in “Nozzle O.D.Size” Data. ----
01 33 3 00005 Error in “Nozzle I.D.Size” Data. ----
01 33 3 00008 Error in “Nozzle V-Groove Size” Data. ----
01 34 3 00001 Error in “Indidual Nozzle Gain or Level” Data. ----
01 35 3 00001 Error in “Nozzle High or Low level offset” Data. ----
01 36 3 00001 Error in “Nozzle Position Offset” Data. ----
01 37 3 00001 Error in “Head Center X or Y Offset” Data. ----
(Cause) Wrong parameters are set.
(Remedy) Set correct parameters.
4.3 Recognition Error IDs and Remedial Procedures
01 10-003 2-164 AFO01ETRP

Recognition Error ID Item Description
01 38 2 00000 Unavailable fiducial mark code was set. ----
01 38 2 00001 “Mark Size D2” is too big, compared with “D1”. ----
01 38 2 00002 “Mark Size D3” is too big, compared with “D1”. ----
01 38 2 00003 “Mark Size D2” is too big, comapred with“D3”. ----
01 38 2 00004 “Window Size” is smaller than “Mark Size”. ----
01 38 2 00005 “Mark Size D2” is not set. ----
01 38 2 00006 “Mark Size D3” is not set. ----
01 38 3 00001 Error in “P.C.B Recognition Mark Data Mark Size ----
D1 or D2 or D3” Data.
01 38 3 00003 Error in “P.C.B Recognition Mark Data Window ----
Size” Data.
(Cause) Wrong parameters are set for the P.E.C. recognition function.
(Remedy) Refer to “Section 2 Pattern Program” in “Vol. 3” for details and set correct
parameters.
4.3 Recognition Error IDs and Remedial Procedures
01 10-003 2-165 AFO01ETRP