CX200-4(Maint) - 第256页
Recognition Error ID Item Description 01 39 2 1301 1 “Lead T ype No.” in “Lead Group 7” is improper . ---- 01 39 2 13012 “Lead T ype No.” in “Lead Group 8” is improper . ---- 01 39 2 13013 “Lead Pitch” in “Lead Group 1” …

Recognition Error ID Item Description
01 39 2 11001 An improper parameter is specified as ----
“Component shape”.
01 39 2 11002 “Mold Size Tolerance X” is larger than “Mold
----
Size X”.
01 39 2 11003 “Mold Size Tolerance Y” is larger than “Mold
----
Size Y”.
01 39 2 11004 “Outward Length Tolerances” are larger than
----
“Outward Length”.
01 39 2 12001 The total of “Corner 1 Dim X” and “Corner 4 Dim
----
X” is larger than “Mold Size X”.
01 39 2 12002 The total of “Corner 1 Dim Y” and “Corner 2 Dim
----
Y” is larger than “Mold Size Y”.
01 39 2 12003 The total of “Corner 2 Dim X” and “Corner 3 Dim
----
X” is larger than “Mold Size X”.
01 39 2 12004 The total of “Corner 3 Dim Y” and “Corner 4 Dim
----
Y” is larger than “Mold Size Y”.
01 39 2 12005 “Electrode Size” is larger than half of “Mold
----
Size X”.
01 39 2 13001 “# of Types” (lead data) is improper.
----
01 39 2 13002 “# of Groups” (lead data) is improper. ----
01 39 2 13003 The total of “# of Leads” (lead data) is too small. ----
01 39 2 13004 “No Detection” is set in all “Insp Condtn” text ----
boxes.
01 39 2 13005 “Lead Type No.” in “Lead Group 1” is improper.
----
01 39 2 13006 “Lead Type No.” in “Lead Group 2” is improper. ----
01 39 2 13007 “Lead Type No.” in “Lead Group 3” is improper. ----
01 39 2 13008 “Lead Type No.” in “Lead Group 4” is improper ----
01 39 2 13009 “Lead Type No.” in “Lead Group 5” is improper. ----
01 39 2 13010 “Lead Type No.” in “Lead Group 6” is improper. ----
(Cause) Wrong parameters are set.
(Remedy) Set correct parameters.
4.3 Recognition Error IDs and Remedial Procedures
01 10-003 2-166 AFO01ETRP

Recognition Error ID Item Description
01 39 2 13011 “Lead Type No.” in “Lead Group 7” is improper. ----
01 39 2 13012 “Lead Type No.” in “Lead Group 8” is improper. ----
01 39 2 13013 “Lead Pitch” in “Lead Group 1” is smaller than ----
“Lead Width”.
01 39 2 13014 “Lead Pitch” in “Lead Group 2” is smaller than ----
“Lead Width”.
01 39 2 13015 “Lead Pitch” in “Lead Group 3” is smaller than ----
“Lead Width”.
01 39 2 13016 “Lead Pitch” in “Lead Group 4” is smaller than ----
“Lead Width”.
01 39 2 13017 “Lead Pitch” in “Lead Group 5” is smaller than ----
“Lead Width”.
01 39 2 13018 “Lead Pitch” in “Lead Group 6” is smaller than ----
“Lead Width”.
01 39 2 13019 “Lead Pitch” in “Lead Group 7” is smaller than ----
“Lead Width”.
01 39 2 13020 “Lead Pitch” in “Lead Group 8” is smaller than ----
“Lead Width”.
01 39 2 13021 “Missing Lead Start” in “Lead Group 1” is too ----
large.
01 39 2 13022 “Missing Lead Start” in “Lead Group 2” is too ----
large.
01 39 2 13023 “Missing Lead Start” in “Lead Group 3” is too ----
large.
01 39 2 13024 “Missing Lead Start” in “Lead Group 4” is too ----
large.
(Cause) Wrong parameters are set.
(Remedy) Set correct parameters.
01 10-003 2-167 AFO01ETRP
4.3 Recognition Error IDs and Remedial Procedures

Recognition Error ID Item Description
01 39 2 13025 “Missing Lead Start” in “Lead Group 5” is too ----
large.
. 01 39 2 13026 “Missing Lead Start” in “Lead Group 6” is too ----
large.
01 39 2 13027 “Missing Lead Start” in “Lead Group 7” is too ----
large.
. 01 39 2 13028 “Missing Lead Start” in “Lead Group 8” is too ----
large.
01 39 2 13029 “Full Length” in “Lead Type 1” is smaller than ----
“Lead Length”.
01 39 2 13030 “Full Length” in “Lead Type 2” is smaller than ----
“Lead Length”.
01 39 2 13031 “Full Length” in “Lead Type 3” is smaller than ----
“Lead Length”.
01 39 2 13032 “Full Length” in “Lead Type 4” is smaller than ----
“Lead Length”.
01 39 2 13033 “Lead Width” and “Full Length” in “Lead Type 1” ----
are not equal.
01 39 2 13034 “Lead Width” and “Full Length” in “Lead Type 2” ----
are not equal.
01 39 2 13035 “Lead Width” and “Full Length” in “Lead Type 3” ----
are not equal.
01 39 2 13036 “Lead Width” and “Full Length” in “Lead Type 4” ----
are not equal
(Cause) Wrong parameters are set.
(Remedy) Set correct parameters.
01 10-003 2-168 AFO01ETRP
4.3 Recognition Error IDs and Remedial Procedures