CX200-4(Maint) - 第275页

Recognition Error ID Item Description 02 ** 3512 ** Error in Lead Detection The detected number of leads is smaller than the set value. 02 ** 3513 ** Error in Lead Detection The detected number of leads is larger than th…

100%1 / 299
Recognition Error ID Item Description
02 ** 3501 ** Error in Lead Detection Some leads cannot be detected because they
are hidden by the nozzle.
02 ** 3502 ** Error in Lead Detection No Lead Detected.
02 ** 3503 ** Error in Lead Detection Corner of Leads Not Detected.
02 ** 3504 ** Error in Lead Detection Ends of Leads Not Detected.
02 ** 3505 ** Error in Lead Detection Ends of Arrayed Leads Not Detected.
02 ** 3506 ** Error in Lead Detection Lead Edges of Corner Not Detected.
02 ** 3507 ** Error in Lead Detection Leads of Corner Not Detected.
02 ** 3508 ** Error in Lead Detection The number of leads at the detected corner is
smaller than the set value.
02 ** 3509 ** Error in Lead Detection Incorrect Lead-to-Lead Distance at Detected
Corner.
02 ** 3510 ** Error in Lead Detection Incorrect Lead-to-Lead Angle at Detected Cor-
ner.
(Cause 1) The results of the lead detection differ from the parameters specified in
the component library data for the selected components.
(Remedy 1) Check the leads of the selected component and the component library
data.
If wrong parameters are set in the component library data, correct them.
01 10-003 2-185 AFO01ETRP
4.3 Recognition Error IDs and Remedial Procedures
Recognition Error ID Item Description
02 ** 3512 ** Error in Lead Detection The detected number of leads is smaller than
the set value.
02 ** 3513 ** Error in Lead Detection The detected number of leads is larger than the
set value.
(Cause 1) The results of the lead detection differ from the parameters specified in
the component library data for the selected components.
(Remedy 1) Check the leads of the selected component and the component library
data.
If wrong parameters are set in the component library data, correct them.
02 ** 8001 ** Data Error Data Error in Process
02 ** 8002 ** Data Error Error in Lighting Data
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Contact our service personnel for details.
02 ** 9001 ** Other Errors Internal Processing Error
02 ** 9002 ** Other Errors Impossible to set the detection window.
02 ** 9003 ** Other Errors Impossible to set the window for arrayed lead
end detection.
02 ** 9004 ** Other Errors Impossible to set the window for lead detection
at the corner.
02 ** 9005 ** Other Errors Impossible to set the window for lead detection.
02 ** 9006 ** Other Errors Angle Calculation Impossible.
02 ** 9007 ** Other Errors Internal Processing Error.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Contact our service personnel for details.
01 10-003 2-186 AFO01ETRP
4.3 Recognition Error IDs and Remedial Procedures
4.3.3 P.E.C. Recognition Errors
AA BB C DDDDD
Detail Code
Secondary Error Classification (1 to 4)
Primary Error Classification (0 to 1)
Classification (03) of Recognition Functions
(a) Error IDs “*” will be filled with detail codes.
(b) When an error ID other than the described ones is issued,
contact our service personnel for some advice.
Table 4B12
Recognition Error ID Item Description
03 00 1 ***** ---- Specified Mark Not Found in Recognizable
Range.
03 00 2 ***** ---- Unstable Image around Fiducial Mark.
03 00 3 ***** ---- Extensive Error in Similitude of Mark Shape.
03 00 4 ***** ---- Extensive Error in Similitude of Mark Shape or
Size.
03 01 1 ***** ---- Specified Mark Not Found in Recognizable
Range.
(Cause 1)The fiducial mark and the fiducial mark coordinates X and Y or the mark
data are not suitable.
(Remedy 1) Follow the steps below to reset the machine to the normal condition.
(1) When the [RETURN] button is pressed, the following recognition
window appears.
Fig. 4B24 Sample Display of Recognition Window
(Continue to the next page. )
01 10-003 2-187 AFO01ETRP
Note
4.3 Recognition Error IDs and Remedial Procedures