• Return the lever to the original position. • Put a new lamp in the lamp socket and push it down until it reaches the bottom of the lamp holder . At this time, direct the side of the lamp where the projected section is …

1.4.6 Lamp Replacement of Light Source Device for Recognition
Lighting
(1) Light Source Devices
Light Source Devices : MHF-D100LRSO-2
MHF-D100LRSC-2
Lamp : LM-100
(2) Lamp Replacement Procedure
• Turn off the power switch of the light source device and check that
the LED (Orange) of the power switch extinguishes.
• Loosen the setscrew on the main body of the light source device and
open the lamp house cover.
• Lift the lever located on the left side of the lamp in the arrow direction.
The lamp will also be lifted up.
• Pull out the lamp straight up from the lamp holder.
• Detach the lamp from the socket.
When the lamp is inserted or pulled out, be sure not to forcibly
screw the terminal into or unscrew it from the socket. Other-
wise, the socket may be damaged.
Fig. 4A83
Do not touch the lamp right after it has been turned
off because it is very hot. Wait for about 3 to 5
minutes or until it cools down.
Be sure to wear gloves made of thick material (for
example, cotton work gloves) to replace the lamp
right after it has been turned off.
CAUTION
Note
0110-003 1-62 AFO01ETRP
1.4 Maintenance Method

• Return the lever to the original position.
• Put a new lamp in the lamp socket and push it down until it reaches
the bottom of the lamp holder. At this time, direct the side of the lamp
where the projected section is located so that the projection matches
the indented section of the lamp holder.
• Close the lamp house cover and shift down the lock lever to fasten
the cover.
• Turn on the power switch of the light source device and check that
the LED (orange) of the power switch illuminates.
• The lamp replacement is completed.
Perform lighting check operation after lamp replacement.
Fig. 4A84
0110-003 1-63 AFO01ETRP
1.4 Maintenance Method

1.4.7 Replacement of Cutter Blade
Time of Replacement
Replace a cutter blade with a new one when the cutting quality has
deteriorated due to wear, cracks, etc.
Replacement Procedure
(1) Zero the feeder carriage and turn off the power to the machine.
(2) Remove Torque Bolts A (M5 × 12, Spring Washer) and B (M5 × 12,
Spring Washer) and detach the cutter cover.
(3) Remove Bolt C (2 pcs., M5 × 8, Spring Washer).
Pull the cutter lower blade forward to detach.
(4) Remove Bolt D (2 pcs., M5 × 16, Spring and Flat Washers).
Pull the cutter upper blade forward to detach.
(5) Follow the reverse procedure to attach the new upper and lower
cutter blades.
Fig. 4A84-1 Rear Side of Machine
After the cutter lower blade is replaced, lubricate the cutter
section.
Refer to “1.3 Maintenance Spots” for details.
01 10-003 1
64 AFO01ETRP
1.4 Maintenance Method
Note