00193364-04 - 第17页
Splice Detection Table Controller 2 A ssembly instructi ons Splice Detection Table Controller SIPLACE HS-50 09/2008 Edition 17 2.3 T ools and Auxiliary Equipment – Metric Hex Ball End Wrench Se t (also called “Allen” Wre…

2 Assembly instructions Splice Detection Table Controller SIPLACE HS-50 Splice Detection Table Controller
09/2008 Edition
16
2.2 Safety instructions
WARNING
The safety instructions from the “Operational safety” chapter of the user manual and servicing in-
structions take precedence over these instructions. 2
The SIPLACE placement machines are supplied with mains voltage.
Consequently parts of these systems carry dangerous voltages! This voltage is present at certain
modules inside the machine base, even when the machine is switched off at the main power
switch.
Incorrect handling of the placement machine or touching live parts of the machine can result in
death or severe injury, and considerable damage to equipment.
BEFORE starting any work, shut down the operating system correctly, then switch the machine
OFF at the main power switch and disconnect from the main power supply. In addition, the com-
pressed air supply must be switched off at the compressed air unit's main valve in the machine
base and vented by actuating the needle valve on the compressed air unit.
There is DANGER for heart pacemaker wearers in the vicinity of the linear motors, as described
in detail in the "Special safety instructions for working in the vicinity of strong magnetic fields"
section of the user manual and service manual.
Always follow the accident prevention regulations, DIN or other standards and special safety
rules applicable in your country.
Pay attention to the information concerning residual voltages in the Operational Safety chapter.
Follow the ESD regulations as described in the operational safety section of the operating
instructions.
During the assembly, always secure the machine to prevent access by other people and to pre-
vent it being switched on again. The procedure is described in the “Locking the machine…” sec-
tion of the user manual.
Working with the SITEST program further increases the risk of accident.
The SITEST program must only be used by authorized and trained personnel.
2
2.2.1 Definitions
2
Note 2
2
2
Splice Detection Table Controller 2 Assembly instructions Splice Detection Table Controller SIPLACE HS-50
09/2008 Edition
17
2.3 Tools and Auxiliary Equipment
– Metric Hex Ball End Wrench Set (also called “Allen” Wrench)
– Diagonal cutters
– #1 Cross Point Screwdriver (also called a “Phillips Head” screwdriver)
– a small flat bladed screwdriver.
2.4 Parts
Contents HS50 Splice Detection table controller package
(item no.: 00119032-01) 2
Number Description item no.:
- 1 table controller unit (TC) 00366007-xx
- 1 cable to the machine 03047976-xx
- 1 adapter power supply 00368490-xx
- installation material

2 Assembly instructions Splice Detection Table Controller SIPLACE HS-50 Splice Detection Table Controller
09/2008 Edition
18
2.5 Preparation
: Familiarize yourself with the new hardware components, as shown in Fig. 2.10 - 1.
2
Abb. 2.10 - 1 Retrofitting kit: splice detection for HS changeover table
2
Table controller HS-50 (TC)
Cable to the machine
Adapter for power supply