Page 33 DH P ositioning System Assembly , Non P/T T46230811 Rev . J This Document Supports Assembly 46230811 Rev J 8. Palm the machine up and push the INTLK RESET push button. 9. Select Channel B: Table Y Axis>Zero Th…

Page 32
T46230811 Rev. J DH Positioning System Assembly, Non P/T
This Document Supports Assembly 46230811 Rev J
Y-axis: 1/4 inch (6.35 mm) from the end of the sheet metal actuator
mounting surface to the edge of the limit switch actuator
block.
3. Using the head drive shaft tool, manually position the head tooling on
both insertion heads to the tool safe position to prevent possible
damage to the insertion tooling during positioning system movements.
4. Place the set up template on the rotary table beneath head 1 and secure
it in position using the locator pins and thumb screws.
5. Activate the IM Diagnostics as follows. Refer to the IM-UPS and IM
Diagnostics documentation for specific details relating to the
operation of the machine terminal.
Select the IM Diagnostics icon.
WARNING
When the machine is in the IM Diagnostics function, power is provided to
the machine. Exercise caution when performing the following
procedures to avoid injury to personnel and equipment.
6. After the IM Diagnostics has completed its initialization, select the
following. Diagnostics>Manual Diagnostics
The Manual Diagnostics screen is displayed
7. In the Outputs side of the Manual Diagnostics screen, select the
following. Section>UIMC 1 Axis Outputs
Set Up Template
Set Up Tool

Page 33
DH Positioning System Assembly, Non P/T T46230811 Rev. J
This Document Supports Assembly 46230811 Rev J
8. Palm the machine up and push the INTLK RESET push button.
9. Select Channel B: Table Y Axis>Zero
The Zero - Table Y Axis dialog screen is displayed.
10. In the Zero - Table Y Axis dialog screen select Default then OK
The Manual Diagnostics screen is displayed.
- In the Channel B: Table Y Axis increment box, click on the up
↑↑
↑↑
↑
or down
↓↓
↓↓
↓ arrows until 1.0 appears in the increment box.
- Click on the + Jog button until the Axis Location for the
Table Y Axis indicator in the Input side of the screen reads 9.0.
11. Select Channel A: Table X Axis>Zero
The Zero - Table X Axis dialog screen is displayed.

Page 34
T46230811 Rev. J DH Positioning System Assembly, Non P/T
This Document Supports Assembly 46230811 Rev J
12. In the Zero - DH X Axis dialog screen select Default then OK
Set up Tool in Outside Formers
The Manual Diagnostics screen is displayed.
- In the Channel A: Table X Axis increment box, click on the up
↑↑
↑↑
↑
or down
↓↓
↓↓
↓ arrows until 1.0 appears in the increment box.
- Click on the + Jog button until the Axis Location for the
Table X Axis indicator in the Input side of the screen reads 9.0.
13. In the Outputs side of the Manual Diagnostics screen, select the
following. Section>UIMC 2 Axis Outputs
14. Select Channel A: DH Span Axis>Zero
The Zero - DH Span Axis dialog screen is displayed.