YS24X_Ope_E - 第140页
3-8 3 Starting and ending pr oduction 1.2 Using the "block skip function" When board data with block distribution performed is loaded, the [Bloc k Skip] button on the Setup screen becomes activ e. Pressing this…

3-7
3
Starting and ending production
1.1.1 Loading the saved data
When you have reset automatic operation while component mounting on a board was in progress, the machine
automatically saves the operation data at the time the operation was reset. That operation data can be reloaded
by pressing the [Read] button on the "Halfway Continue" dialog box. Then you can resume automatic operation
to mount components from the stopped point. Since the saved operation data includes error information,
components will be mounted at the points where for some reason the machine failed to mount components.
Automatic operation restarts
after loading saved data.
1
5
BLOCK NO.1
Resuming component mounting
BLOCK NO.2
2
6
3
7
4
8
1
5
2
6
3
7
4
8
1
5
BLOCK NO.1 BLOCK NO.2
2
6
3
7
4
8
1
5
2
6
3
7
4
8
: mounted
: not mounted
Reset
23301-L4-00
1.1.2 Editing mount flags
The "Halfway Continue" dialog box also allows you to mount components at specific mounting points by
specifying the mount data numbers. When you have paused and reset operation data while component
mounting was in progress, you can reload that operation data by pressing the [Read] button and then edit each
mounting point as necessary by using the [MntFlg] button.
Editing mount flags
Example of Dual-lane
Offset No. selection box
Mounted flag (checkmark) [MntFlg] button
24305-L4-00
n
NOTE
When the offset function for multi-board panels is used, component mount data for each block can be edited by
selecting the offset No. Note that this function can be used just for the first board after the operation is resumed, with
routine mounting operation beginning from the next board.

3-8
3
Starting and ending production
1.2 Using the "block skip function"
When board data with block distribution performed is loaded, the [Block Skip] button on the Setup screen
becomes active. Pressing this button opens the "Block Skip Utility" dialog box to enable the block skip
function. Use this function when you want to skip mounting components in each block.
n
NOTE
When producing boards using both lanes of dual-lane machines, use the [Lane select] button to select the lane
before continuing operation.
n
NOTE
The block skip function can only be used for board data with block distribution performed (with note data). See the
separate "YS Series Programming Manual" for information on block distribution.
c
performed.
This function cannot be used for board data if it has 512 or more block offsets before block distribution is performed.
[Block Skip] button
"Block Skip Utility" dialog box
24320-L4-00
n
NOTE
The block skip function is enabled when the [Block Skip] button is ON (pressed).
To disable this function, press the [Block Skip] button to turn it OFF.
This function is also disabled when board data with a different name is loaded or the power is turned OFF. The [Block
Skip] button on the Setup screen automatically turns OFF in this case.
Component mounting in each block will not be skipped unless the [Block Skip] button is ON.

3-9
3
Starting and ending production
1.2.1 Selecting the blocks
To select the blocks where you want to skip mounting components, place a check mark in the check boxes for
those blocks. (Directly click the check boxes or press the [Check] button after selecting the blocks.)
After placing the check marks, press the [OK] button to complete the settings. The [Block Skip] button on the
Setup screen then turns ON.
[Check] button
Selecting the blocks to be skipped
Place a check mark for the blocks to be skipped.
24321-L4-00
Data for the blocks that are set to be skipped can be checked on the [Mount] parameter tab of the Board
screen. The message "Skip" is displayed in the "Skip" column of those data as shown below, and they cannot
be edited on this screen. The "Original Block No." shows the block to which the data to be skipped belongs.
Block No. to which each data belongs.
Checking the blocks
Message "Skip" is displayed.
24322-L4-00