YS24X_Ope_E - 第155页
3-23 3 Starting and ending pr oduction 3.7 Fiducial T he [Fiducial] tab screen shows the recognition results of fiducial marks such as "Board, Bloc k", "2 Point Local" and "P oint" fiducial …

3-22
3
Starting and ending production
3.6 Retry
The [Retry] tab screen displays the history or the past 100 errors.
Monitor: Retry
24314-L4-00

3-23
3
Starting and ending production
3.7 Fiducial
The [Fiducial] tab screen shows the recognition results of fiducial marks such as "Board, Block", "2 Point Local"
and "Point" fiducial marks.
Monitor: Fiducial
Example of Dual-lane
24315-L4-10
• Align X, Y, R
Shows the difference between the recognition results and the board data input values, by plus or minus values.
• Align Ratio
Shows the rate of expansion of the board, calculated by using the X, Y and R offset values.
• Result
Shows the recognition results as a "Pass" or "Unfinished ". The "Unfinished" message changes to "Pass" after the mark has
been recognized successfully.

3-24
3
Starting and ending production
3.8 Badmark
The [Badmark] tab screen shows the recognition results of badmarks such as "Board, Block" and "Local"
badmarks.
Monitor: Badmark
Example of Dual-lane
24316-L4-10
• X, Y
Shows the board data input values (by taking block offset amount into account).
• Result
Makes an "OK" or "NG" decision based on the badmark recognition result.
OK : Work is performed when no badmark is recognized.
NG : Work is not performed when a badmark is recognized.