YS24X_Ope_E - 第41页

1-4 1 Part names and functions 2.2 Operation panel buttons T he operation panel buttons are provided on the front and rear of the machine to run major commands frequently used to operate the mac hine. Each button is lit …

100%1 / 165
1-3
1
Part names and functions
2. Operation panel and data input unit
Standard machines are equipped with an operation display, operation panel buttons, a keyboard and a
mouse on the front and rear (option) of the machine, to operate the machine and make data settings. The
functions of these units are explained below.
Operation panel and data input unit
Operation panel button Operation display (touch screen is optional)
MouseKeyboard
23101-L4-00
2.1 Keyboard and mouse
This machine is equipped with a keyboard and mouse as standard features to operate the machine or edit data
settings. To select a menu button or parameter item on the operation screen, click it with the left mouse button.
Mouse in holder
Keyboard and mouse
Keyboard Mouse
Mouse pad
23102-L4-00
c

Store the mouse in holder when not in use or it may drop and be damaged.
1-4
1
Part names and functions
2.2 Operation panel buttons
The operation panel buttons are provided on the front and rear of the machine to run major commands
frequently used to operate the machine. Each button is lit while turned on. (The operation panel buttons light
up in the same colors specified by the signal light.)
Operation panel buttons
23103-L4-00
n
Operation panel button functions
Button name Use the button to: OFF ON
ACTIVE
Enable other keys. (The front and rear
[ACTIVE] keys cannot be turned on
simultaneously.)
After machine has started.
• The other table has access
rights to operate machine.
• Has access rights to
operate machine.
READY
Release emergency stop and turn the
servo on.
• SERVO OFF
(Motor power OFF)
• SERVO ON
(Motor power ON)
RESET
Stop automatic operation and return to
standby for board production.
• Machine is in normal operation
or stopped.
• Machine has been reset.
START (green)
Perform component placement
according to board data.
• Machine is stopped.
• Machine is in normal operation.
[Flash]
Pause or step operation
STOP (Red/White)
Interrupt automatic operation. (Press
START to resume operation.)
• Machine is in normal operation. • Error occurred.
ERROR CLEAR
(Yellow/Blue)
Stop buzzer sound and clear error
screen.
• Machine is in normal operation. • Error occurred.
EMERGENCY STOP
Trigger emergency stop. Turn to the
right to release it.
n
NOTE
The [ACTIVE] button is provided on both front and rear (option) panels, but cannot be turned on simultaneously. This
means that the [READY], [START], [ERROR CLEAR] and [RESET] buttons are enabled only when the [ACTIVE] key on the
same panel is turned on. (The [STOP] button can be used when the [ACTIVE] button is either on or off.)
The keyboard is enabled only when the [ACTIVE] key on the front panel is on.
1-5
1
Part names and functions
3. Head assembly
The head assemblies are mounted on two XY axes located on the A and B tables of the machine and move to
pick up and place components.
Head assembly
Fiducial camera lighting unit Fiducial camera lighting unit
10-in-line multi-head
Handle for moving
head assembly
(rear side)
23104-L4-00
n
NOTE
The mounting position of the fiducial camera lighting unit may vary depending on the specifications. (Note that the
double-fiducial camera specifications are optional.)
n
Dual - stage
• Right-to-left ow: The lighting unit is mounted on the head No. 10 side of the A-table head and B-table head (see
the figure below) when the machine has the single fiducial camera specifications.
• Left-to-right ow: The lighting unit is mounted on the head No. 1 side of the A-table head and B-table head (see
the figure below) when the machine has the single fiducial camera specifications.
n
Single-lane / Dual-lane
• Right-to-left ow: The lighting unit is mounted on the head No. 1 side of the A-table head and on the head
No. 10 side of the B-table head (see the figure below) when the machine has the single
fiducial camera specifications.
• Left-to-right ow: The lighting unit is mounted on the head No. 10 side of the A-table head and on the head
No. 1 side of the B-table head (see the figure below) when the machine has the single
fiducial camera specifications.
A
B
Head layout
10
10
1
1
Front of machine
23105-L4-00