2-1 2  asic operation 1. Before operation The following explains how to cancel emergency stop and clear errors. Read before operating the machine. n Cautions during machine operation • Do not turn off the compressed air…

100%1 / 165
Chapter 2 Basic operation
Contents
  1
1.1 Canceling emergency stop 2-1
1.2 Clearing an error 2-2
1.3 Typical errors and troubleshooting 2-3
  8
  8
2.2 Setup screen 2-11
2.3 Unit screen 2-13
3. Starting and stopping the machine 2-19
3.1 Pre-operation check 2-20
3.2 Starting the machine 2-21
3.3 Warming up the machine 2-23
  5
3.4.1 Conveyor unit setup flow 2-26
4. Preparing the component supply unit 2-29
4.1 Tape feeders 2-29
4.1.1 Setting the tape 2-29
4.1.2 Setting a tape feed pitch 2-34
4.1.3 Installation on a mounter 2-38
4.2 Wide multi-stick feeder 2-39
4.2.1 Installation of tracks and sticks 2-39
4.2.2 Installation on a mounter 2-42
4.3 Tray changer (sATS
II
 3
4.3.1 Setting the component trays in the pallet 2-44
4.3.2. Setting the pallet in the magazine 2-45
4.3.3 Replacing a magazine or pallets 2-47
5. Settings on the mounter side 2-49
5.1 Setting the "Package" parameter. 2-49
  4
2-1
2
asic operation
1. Before operation
The following explains how to cancel emergency stop and clear errors. Read before operating the machine.
n
Cautions during machine operation
Do not turn off the compressed air during operation. The machine may malfunction, as pneumatic devices are not
correctly controlled.
Before beginning maintenance work, always make sure that no air pressure remains in air cylinders.
n
Cautions during power outages
If a power outage (blackout) occurs during automatic machine operation, always turn the main power switch off to
prevent faulty operation or machine damage after power has been restored. Also remove the boards that remain in the
machine.
1.1 Canceling emergency stop
Follow these steps to cancel emergency stop.
1
Release the emergency stop button.
When the emergency stop button is pressed, turn it clockwise to release it.
2
Check safety.
Before continuing the procedure, check the surrounding area for safety.
3
Press the [READY] button.
Pressing the [READY] button on the operation panel turns on the servomotors.
c


[READY] button
Press the [READY] button to turn on the servo.
23200-L4-00
4
Check the signal light and screen display.
Check that the red lamp of the signal light is off and the emergency stop sign on the top left (status
area) of the operation screen is now off.
2-2
2
asic operation
1.2 Clearing an error
If an error occurs a buzzer sounds and a warning screen appears. To clear the error, use the following steps.
1
Turn off the buzzer.
Press the [ERROR CLEAR] button on the operation panel or the [BUZZER OFF] button on the error screen
to turn off the buzzer.
2
Check the cause of the error.
Possible causes are displayed on the lower part in the error screen, so check or make a note of the
description.
3
Clear the error screen.
Press the [ERROR CLEAR] button again or the [ERROR CLEAR] button on the error screen to clear the
error screen.
4
Check the signal light and screen display.
Check that the yellow lamp of the signal light is off and the error message on the left of the status area
on the operation screen is now off.