SIPLACE D3 规格说明书英文版 - 第41页

41 Technical Data Electrical Connection, Interfaces and Compressed Air Connection Compressed air connection SMEMA/Siemens interface PC and LAN connection Power connector 5 x 6 mm² ca ble with CEKON plug 5 x 32 A (3 x 208…

100%1 / 60
40
Technical Data
Electrical Ratings and Compressed Air Supply
Electrical ratings
Supply voltage 3 x 200 VAC ± 5 %; 50/60 Hz (Japanese version)
3 x 208 VAC ± 5 %; 50/60 Hz (U.S.A. version)
3 x 230 VAC ± 5 %; 50/60 Hz
3 x 380 VAC ± 5 %; 50/60 Hz
3 x 400 VAC ± 5 %; 50/60 Hz (European version)
3 x 415 VAC ± 5 %; 50/60 Hz
Fuses 3 x 32 A (3 x 200 VAC / 3 x 208 VAC / 3 x 230 VAC)
3 x 16 A (3 x 380 VAC / 3 x 400 VAC / 3 x 415 VAC)
Power connector 5 x 6 mm² cable with CEKON plug 5 x 32 A
(3 x 200 VAC / 3 x 208 VAC / 3 x 230 VAC)
5 x 4 mm² cable with CEKON plug 5 x 16 A
(3 x 380 VAC / 3 x 400 VAC / 3 x 415 VAC)
Nominal apparent power 4.1 kVA
Active power 2.15 kW
Rated current consumption 9.7 A / 3 x 400 VAC
Compressed air supply
Compressed air ratings
p
min
p
max
0.5 MPa = 5.0 bar
1.0 MPa = 10 bar
Operating pressure 0.48 MPa ± 0.025 MPa (4.8 bar ± 0.25 bar)
Compressed air connection R 3/4" internal thread (pipe thread) with 1/2" hose connector
Compressed air consumption
with four tape cutters
2 x C&P12 / TH
a
a) Under normal atmospheric conditions at 20°C and 1013 hPa
550 Nl/min
300 Nl/min with vacuum pump
Compressed air specification
Particle size 5 µm ISO class 3
Particle density 5 mg/m³ ISO class 3
Maximum oil content 0,01 mg/m³ ISO class 1
Pressure dewpoint + 3°C ISO class 4
41
Technical Data
Electrical Connection, Interfaces and
Compressed Air Connection
Compressed air
connection
SMEMA/Siemens interface
PC and LAN connection
Power connector
5 x 6 mm² cable with CEKON plug 5 x 32 A (3 x 208 VAC / 3 x 230 VAC)
5 x 4 mm² cable with CEKON plug 5 x 16 A (3 x 380 VAC / 3 x 400 VAC / 3 x 415 VAC)
Power supply connection
42
Technical Data
Dimensions and Set-Up Conditions
Length
with both extension kits
with one extension kit
with no extension kits
2380 mm
2103 mm
1826 mm
Width of the basic machine
with CO changeover table (locations 1 + 4)
with CO changeover table (locations 2 + 3)
including monitors
with keyboards
2815 mm
2395 mm
2766 mm
2804 mm
Height of the machine
with indicator lamp
with protective covers folded up
max. 1863 mm
1990 mm (PCB transport height 830 mm)
2060 mm (PCB transport height 900 mm)
2090 mm (PCB transport height 930 mm)
2112 mm (PCB transport height 950 mm)
Machine ground clearance 120 mm (PCB transport height 830 mm)
190 mm (PCB transport height 900 mm)
220 mm (PCB transport height 930 mm)
240 mm (PCB transport height 950 mm)
Weight
Machine with component changeover table
Full configuration with feeder modules
3790 kg
4171 kg
Footprint 6.70 m²
Load per unit area
a
a) The load per unit area calculation included an additional working space of 0.5 m on each side of the ma-
chine.
5.84 kN/m²
Number of machine feet 6
Maximum noise emissions 75 dB (A)
Room temperature between 15 °C and 35 °C
Atmospheric humidity 30 to 75 % (no higher than 45% on average
to prevent any possibility of condensation
on the machine)