00195044-10_UM_VisionTeachStation_DE EN - 第156页

8 Starting the vision teach station Vision Teach Station User Manual 8.1 Switching on the vision teach station 12/2012 Edition 156 8 Starting the vision teach station Check the power cable connections before you switch o…

100%1 / 184
Vision Teach Station User Manual 7 Software
12/2012 Edition 7.6 Features as of the 4.3.1 VTS version
155
7.6.5.2 Results from a test suite
The results are displayed after every test run.
"Result": Current result ("Successful", "Failed" or "Deviation")
"Previous measurement result": Result of the test suite run using the Vision data prior to the last
change ("Successful", "Failed" or "Deviation").
"Expected result": Here the user can specify the expected result of the measurement ("Success-
ful", "Failed" or "Specified position"). This is intended to assist users in determining the objectives
that they wish to achieve by manipulating the test suite Vision data.
Creating a test suite
A test suite can be created in the "Measurement contexts" and "Test data" views.
A new test suite can be created by clicking "New test suite" in the "Test suites" view.
Editing a test suite
A test suite file can be renamed or deleted when it is selected in the folder hierarchy view.
Measurement contexts of a test suite can be deleted, copied or added.
Editing the Vision data of a test suite
It is possible to select the Vision data of a test suite from a SIPLACE Pro component shape, a
measurement context file or a Vision data XML file.
The "Reset Vision data" button deletes the Vision data from the test suite.
It is not possible to perform a test run if a test suite does not possess any Vision data.
The Vision data of a test suite can be edited by opening a measurement context of the test suite
in the SIPLACE Vision views.
7.6.6 Software licensing
See section 7.4, page 150. 7
7.6.7 Display of station measurement contexts
See section 10.2.5, page 170. 7
8 Starting the vision teach station Vision Teach Station User Manual
8.1 Switching on the vision teach station 12/2012 Edition
156
8 Starting the vision teach station
Check the power cable connections before you switch on the vision teach station.
Base module and PC see section 4, from page 113.
Cameras see section 5, from page 116.
WARNING 8
NEVER remove the 26-pin ribbon cable from the Collect&Place head camera while the base
module is switched on as this could damage the LED driver board for the camera.
8.1 Switching on the vision teach station
Switch the base module on at the power switch.
The three LEDs on the back of the base module light up.
Switch the PC on.
Log in as Administrator (see section 7.2, page 140) or as a user.
8.2 Starting the vision teach station application
Double-click on the "Teach Station" icon to start the application. The application will detect any
cameras that are connected. The live image of the first camera is displayed on the application's
starting screen. If there are two cameras connected, you can toggle between the two.
Vision Teach Station User Manual 8 Starting the vision teach station
12/2012 Edition 8.3 Error messages when starting the application
157
8.3 Error messages when starting the application
The following error messages may appear when you start the application:
8.3.1 No camera was detected
Check that the base module is switched on and that all 3 LEDs light up.
If the three LEDs light up, then the + 24 V- (red), + 15 V- (yellow) and + 42 V- (green) supply
voltages are present (see section 4.2, page 114). 8
If one of the LEDs does not light up, contact SIPLACE Service. 8
If all 3 LEDs do not light up, check the 2.5 A fuse (item 1 in Fig. 8
4.2 - 1, page 114). 8
Check whether the CAN bus cable between the PC and the base module or between the base
module and the stationary camera is connected correctly.
Exit and restart the vision teach station application.
8.3.2 Camera not responding
If a stationary camera is concerned (type 33/type 25):
Check that the orange camera bus cable is connected between camera and PC.
If a head camera is concerned:
Check that the orange camera bus cable is connected on the back of the basic module
(connection (5) in Fig. 4.2 - 1, page 114) and to the PC.
Check whether there are bent connection pins on the plugs of the "adapter for head camera"
(Fig. 5.2 - 9, Seite 128) .
If the camera still is not detected, contact SIPLACE Service.
8.3.3 There is a vision teach station application running already
Exit the application and then start it again.
8.3.4 Error: LED self-test failed. Not all LEDs are working properly
One or more LEDs for the camera illumination has failed.
Replace the defective camera.