6 Repairs to SmartFeeder 4 mm X 6.12 Flap/drip tray for cover foil Service Manual SIPLACE SmartFeeder 4 - 104 mm X 11/2017 67 6.12.1 Replacing the drip tray and shaft ► Carefully place the feeder module with the left sid…

100%1 / 286
6 Repairs to SmartFeeder 4 mm X
6.12 Flap/drip tray for cover foil
66 Service Manual SIPLACE SmartFeeder 4 - 104 mm X 11/2017
6.12 Flap/drip tray for cover foil
Required spare part
Fig.16: Drip tray and shaft
Feeder module Position Item no. Designation
SmartFeeder 4mmX 1 03119392Sxx Drip tray for cover foil X4Smart
2 03004081-xx Shaft for D2 foil flap X8
Required tools
●
TORX screwdriver size T8, with 0.6Nm
●
Phillips screwdriver 0.9Nm
6 Repairs to SmartFeeder 4 mm X
6.12 Flap/drip tray for cover foil
Service Manual SIPLACE SmartFeeder 4 - 104 mm X 11/2017 67
6.12.1 Replacing the drip tray and shaft
► Carefully place the feeder module with the left side down on a stable, level and clean surface.
► Remove the right side cover (see 6.3.3 "Removing the Right Side Cover" [}32])
► Remove the "insertion foil container" (see 6.14.1 "Replacing the foil container" [}69]).
► Clean the foil container thoroughly and remove all foil and adhesive residues.
► Remove the "cover foil drip tray"(1) and, if
needed, the "shaft D2"(2). The shaft is just inser-
ted into the foil container.
► Insert the (new) "shaft D2"(1) in the position
shown in the foil container, as far as the stop.
► Push the (new) cover foil drip tray onto the "shaft
D2".
► Fit the "insertion foil container" (see 6.14.1 "Replacing the foil container" [}69]).
► Fit the right side cover (see6.3.4 "Fitting the Right Side Cover" [}33]).
6 Repairs to SmartFeeder 4 mm X
6.13 Foil disposal blade
68 Service Manual SIPLACE SmartFeeder 4 - 104 mm X 11/2017
6.13 Foil disposal blade
Required spare part
Fig.17: Blade partition wall
Feeder module Item no. Designation
SmartFeeder 4mmX 00341370Sxx Blade partition wall
NOTICE
Pay attention when preparing the individual blades. Individual blades must be broken at the
cutter edge. Ensure all safety precautions are observed.
Required tools
●
TORX screwdriver 0.6Nm, size T8
WARNING
Risk of injury
The edge of the blade is very sharp. Make sure that you always use a pair of tweezers
when removing and fitting the blade.
6.13.1 Removing the Blade Partition Wall
► Place the feeder on a stable, level and clean surface.
► Open the flap.
► Loosen the screw fastening the blade and remove the old blade.
6.13.2 Fitting the Blade Partition Wall
► Place the new blade in position and tighten the screw.
CAUTION
► The blades are sharp, take necessary safety precautions.