00198505-01_SM_SIPLACE_SmartFeeder_EN - 第93页

7 Repairs to SmartFeeder 8 mm X 7.6 Splice sensor Service Manual SIPLACE SmartFeeder 4 - 104 mm X 11/2017 93 ► Fasten the actuator axis with a fitting screw Use a 1.5mm Allen key for this. ► Fasten the pickup window (se…

100%1 / 286
7 Repairs to SmartFeeder 8 mm X
7.5 Pickup window
92 Service Manual SIPLACE SmartFeeder 4 - 104 mm X 11/2017
7.5.3 Removing the actuator
Remove the pickup window 7.5.1 "Removing the
Pickup Window" [}90]).
Remove the fitting screw shown in the diagram.
Use a 1.5mm Allen key.
Pull the actuator on the righthand side of the
feeder module out of the base unit.
7.5.4 Fitting the actuator
Push the actuator on the righthand side of the
feeder module into the base unit as shown.
During this, push the actuator axis into the hole
shown in the diagram.
7 Repairs to SmartFeeder 8 mm X
7.6 Splice sensor
Service Manual SIPLACE SmartFeeder 4 - 104 mm X 11/2017 93
Fasten the actuator axis with a fitting screw
Use a 1.5mm Allen key for this.
Fasten the pickup window (see 7.5.2 "Fitting the
Pickup Window" [}90]).
7.6 Splice sensor
NOTICE
Removing retrofitted splice sensors
Each SmartFeeder 8mmX is prepared for using a splice sensor, although it is supplied
without the splice sensor. To re-establish this delivery state, you need to remove any retro-
fitted splice sensors before you send the feeder module back to the manufacturer for re-
pairs.
Required spare part
Splice sensor Dummy splice sensor
Feeder module Item no. Designation
SmartFeeder 8mm X 03107028 -xx Splice sensor X8Smart assy.
03104558 -xx Dummy splice sensor X8Smart
Required tools
TORX screwdriver 0.6Nm, size T8
7 Repairs to SmartFeeder 8 mm X
7.6 Splice sensor
94 Service Manual SIPLACE SmartFeeder 4 - 104 mm X 11/2017
7.6.1 Replacing the Dummy with a Splice Sensor
Place the feeder module in a stable, upright posi-
tion.
The dummy splice sensor(1) is located behind the
pickup window and is held by the "splice sensor filling
piece"(2).
Loosen the TORX screw(3), with which the filling
piece(2) is fixed, until you can move the filling
piece.
Move the filling piece in the direction of the arrow
until you reach the right-hand stop.
Push the dummy splice sensor (1) next to the
filling piece until the two pins on the front of the
dummy is free.
Pull the dummy up and out.