Special Design 2 Assembly instruct ions Special design for bulk case feeder for wire jumper s (00166278-01) 04/2007 Edition 11 2 Assembly instructions S pecial design for bulk case feeder for wire jumpers (00166278-01) 2…

100%1 / 18
1 Montageanleitung SOKO Schüttgutförderer für Drahtbrücke (00166278-01) SOKO
Ausgabe 04/2007
10
Special Design 2 Assembly instructions Special design for bulk case feeder for wire jumpers (00166278-01)
04/2007 Edition
11
2 Assembly instructions
Special design for bulk case feeder
for wire jumpers (00166278-01)
2.1 Description of the functional units on the feeder
2
Component container
Vibration intensity
setting
Control
Pick-up position
Feeding rail
Separating stroke
setting
Lifting magnet
2 Assembly instructions Special design for bulk case feeder for wire jumpers (00166278-01) Special Design
04/2007 Edition
12
2
2
The feeder activation circuit provides the cycle time between pick-up operations that is set in
SIPLACE Pro. 2
A knurled screw which is secured with a grub screw is used to set the vibration intensity. This set-
ting always applies to both tracks. 2
The component container must always be filled with at least 6000 components. 2
The components are separated via a series of chicanes through to the infeed to the feeding rails.
The pressure of the following components pushes the components into the pick-up position. To
prevent the components becoming caught up on any burrs, the pick-up position is separated via
a lifting magnet 1/10 mm before pick-up. This stroke is adjustable, but a larger separation is not
recommended. 2
2
Feeding rail cover
Separation