2.3 Working principle with circuit diagrams
If connectors X34 (PA 1) and X35 (PA 2) are plugged in on the conversion board (00359425-xx),
then the option is activated and the signal lines can be evaluated accordingly. 2
2
Fig. 2.3 - 1 Conversion board HS-60; HF (part no. 00359425-xx)
2
2
2
2
2
2
2
2
2
2
2
2

Installation instructions Vacuum Tooling Neology (00166109-01) SIPLACE HF3
02/2005 Edition
28
Working principle of the vacuum switch: 2
2
For programming, see 1.6.3. 2
If the vacuum threshold cannot be reached, then the placement process cannot be started. 2
Once the placement process has ended, the vacuum must be reduced to the set threshold (150
mbar) so that the lifting table can move down. 2
The vacuum threshold is only checked immediately after the lifting table has moved up. 2
A drop in vacuum during placement cannot be detected. 2
0 bar2
- 1 bar1
A 21
H 11
Output 11
Output 21
- 150 mbar1
- 700 mbar1
if 1==>
signal that
placement may start 1
if 1==>
signal that the lifting
table may be lowered 1

Installation instructions Vacuum Tooling Neology (00166109-01) SIPLACE HF3
02/2005 Edition
29
Circuit diagram for wiring the option 2
2
00166109-01
Vacuum tooling wiring
Vaacuum tooling circuit diagram
Note!