Vakuumtooling Neology HF3 - 第41页
Installation instructions Vacuum Tooling Neology (00166109-01) SIPLACE HF3 02/2005 Edition 41 2 Fig. 2.7 - 2 Vacuum built up in plac ement area 1 is too low T roubleshooting 2 – Check wh ether all the v acuum holes ar e …

Installation instructions Vacuum Tooling Neology (00166109-01) SIPLACE HF3
02/2005 Edition
40
2.7 Possible error messages and troubleshooting
2
Fig. 2.7 - 1 Error message for lack of compressed air
Troubleshooting 2
– Check the compressed air connections
– Check the set pressure on the maintenance unit
2
2
2
2
2
2
2
2

Installation instructions Vacuum Tooling Neology (00166109-01) SIPLACE HF3
02/2005 Edition
41
2
Fig. 2.7 - 2 Vacuum built up in placement area 1 is too low
Troubleshooting 2
– Check whether all the vacuum holes are covered (the as-delivered setting allows placement
with just one vacuum hole open)
– Check whether there are any components or dirt on the vacuum plate

Installation instructions Vacuum Tooling Neology (00166109-01) SIPLACE HF3
02/2005 Edition
42
2
Fig. 2.7 - 3 The vacuum cannot be fully dissipated after the placement process.
Troubleshooting 2
– Check the vacuum tooling connections