MV-9_Chapter 5. Teaching.pdf - 第284页

MV -9 Use r Manual 5- 284 reference position is the red window . 5.10.5 Inspec tion M ode Sett ing Set the inspection m ode. ① Middle V alu e : Inspect i t by using the m i ddle val ue of the m e asured he i ghts and the…

100%1 / 286
错误!使用“开始”选项卡将 제목 2 应用于要在此处显示的文字。错误!使用“开始”选项卡将 제목 2 应用
于要在此处显示的文字。 .
5-283
5.10.3 Selection of Reference Position
Select the reference position window and select “Reference Position” on the parameter
window..
5.10.4 Designation of Reference Position
Select the height inspection window and the reference position window, and tie them
into one part.
Select the tied part and enter „Edit‟ mode.
Select the height inspection window and click “Reference ID” on the parameter
window.
Click the reference position window and designate the reference position. .
The ID of the window designated next to “Reference ID” is displayed.
Example) The window selected in the figure below is the height inspection window and the
MV-9 User Manual
5-284
reference position is the red window.
5.10.5 Inspection Mode Setting
Set the inspection mode.
Middle Value: Inspect it by using the middle value of the measured heights and the
inspection standards.
Percentage: Inspect it by using the ratio of the heights satisfying the inspection
standards.
- Conduct the ratio-based inspection with the data satisfying the minimum and maximum
heights.
5.10.6 Criteria Setting
Click “Measure”
- Measure and display the height.
Inspection Standard Setting
- Set the reference value of the minimum and maximum heights in reference to the
measured heights.
错误!使用“开始”选项卡将 제목 2 应用于要在此处显示的文字。错误!使用“开始”选项卡将 제목 2 应用
于要在此处显示的文字。 .
5-285
Setting of Additional Options
+
- They are activated during the inspection of middle values.
- During the height measurement, exclude the heights lower than the designated height.
5.10.7 Inspection Results
Results for Middle Value Mode
- The inspection results of the height are displayed in the form of “Minimum Height <
Inspection Result Height < Maximum Height”.
- In case of detecting the poor quality, „Lifted Package‟ is displayed..
Results for Percent Mode
- The inspection results of the height are displayed in the form of “Reference Value <
Current Percentage”.
- In case of detecting the poor quality, „Lifted Package‟ is displayed.